Instrumentation cables for analogue and digital signal transmission in process plants, oil and gas projects, petrochemical facilities, power stations and industrial automation systems.
Instrumentation cables for analogue and digital signal transmission in process plants, oil and gas projects, petrochemical facilities, power stations and industrial automation systems.
Oil and gas
Petrochemical plants
Process control
Power generation
Industrial automation
Cable Construction
Plain or tinned copper conductor
PE, XLPE, PVC or LSZH insulation
Individual and/or overall screen
Drain wire
PVC, PE or LSZH outer sheath
Standards And Cable Types
BS 5308
PAS 5308
EN 50288-7
IEC 60332
IEC 60754
Instrumentation Selection Data
Voltage rating
300/500 V, 500 V or customer-specified
Cable element
Pairs, triples or multicore
Conductor
Class 1 solid, Class 2 stranded or Class 5 flexible copper
Insulation / sheath
PVC, LSZH, PE, oil-resistant compounds
Screening
Individual screen, overall screen, or both
Mechanical protection
SWA, braid or standard depending on installation
Fire performance
Flame retardant, LSZH or fire resistant cable types available
Electrical data
Conductor resistance, insulation resistance, mutual capacitance, L/R ratio, OD and weight by exact reference
Find The Exact Cable Size
Open a cable construction page, then select the voltage, conductor material, core layout and cross-section row that matches your enquiry. Each row opens a cable specification sheet for quote preparation.
EN 50288-7 Instrumentation Cable Constructions
Instrumentation cable pages are organised by insulation/sheath material, pair/core/triple layout, collective or individual screening and mechanical protection. Open a construction page to compare exact pair count, conductor size, resistance, mutual capacitance, L/R ratio, OD, weight and cable specification sheets.
EN 50288-7 RE-2X(St)H Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)H SWA Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)H Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)H SWA Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)H CWB Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining XLPE insulation, LSZH sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2X(St)H Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)H SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)H CWB Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, LSZH sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2X(St)H PiMF Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2X(St)H PiMF SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2X(St)H Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)H SWA Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)H Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)H SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)H PiMF Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2X(St)H PiMF SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2Y(St)H Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)H SWA Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)H Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)H SWA Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)H CWB Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PE insulation, LSZH sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2Y(St)H Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)H SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)H CWB Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, LSZH sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2Y(St)H PiMF Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2Y(St)H PiMF SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2Y(St)H Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)H SWA Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)H Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)H SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, LSZH sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)H PiMF Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2Y(St)H PiMF SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, LSZH sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2X(St)Y Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)Y SWA Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)Y Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)Y SWA Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)Y CWB Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining XLPE insulation, PVC sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2X(St)Y Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)Y SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)Y CWB Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, PVC sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2X(St)Y PiMF Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2X(St)Y PiMF SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2X(St)Y PiMF DSTA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining XLPE insulation, PVC sheath, individual pair aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2X(St)Y Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)Y SWA Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)Y Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2X(St)Y SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2X(St)Y PiMF Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2X(St)Y PiMF SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining XLPE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2Y(St)Y Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)Y SWA Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)Y Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)Y SWA Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)Y CWB Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PE insulation, PVC sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2Y(St)Y Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)Y SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)Y CWB Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, PVC sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-2Y(St)Y PiMF Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2Y(St)Y PiMF SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2Y(St)Y PiMF DSTA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PE insulation, PVC sheath, individual pair aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-2Y(St)Y Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)Y SWA Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)Y Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-2Y(St)Y SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-2Y(St)Y PiMF Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-2Y(St)Y PiMF SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PE insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-Y(St)Y Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-Y(St)Y SWA Multicore Instrumentation Cable is an instrumentation cable construction for multi-core signal and control circuits where pair twisting is not required, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-Y(St)Y Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-Y(St)Y SWA Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-Y(St)Y CWB Single Pair Instrumentation Cable is an instrumentation cable construction for single analogue or digital instrument loop, combining PVC insulation, PVC sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-Y(St)Y Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-Y(St)Y SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-Y(St)Y CWB Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PVC insulation, PVC sheath, copper wire braid screen for emc protection and mechanical stability and a protected installation profile.
EN 50288-7 RE-Y(St)Y PiMF Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PVC insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-Y(St)Y PiMF SWA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PVC insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-Y(St)Y PiMF DSTA Multipair Instrumentation Cable is an instrumentation cable construction for marshalling cabinets, DCS racks, junction boxes and multi-loop field instrument wiring, combining PVC insulation, PVC sheath, individual pair aluminium/polyester screens plus collective overall screen and mechanical protection.
EN 50288-7 RE-Y(St)Y Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-Y(St)Y SWA Single Triple Instrumentation Cable is an instrumentation cable construction for three-wire transmitter and RTD style instrumentation circuits, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-Y(St)Y Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and a protected installation profile.
EN 50288-7 RE-Y(St)Y SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PVC insulation, PVC sheath, overall aluminium/polyester tape screen with tinned copper drain wire and mechanical protection.
EN 50288-7 RE-Y(St)Y PiMF Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PVC insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.
EN 50288-7 RE-Y(St)Y PiMF SWA Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PVC insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and mechanical protection.
Instrumentation cables for analogue and digital signal transmission in process plants, oil and gas projects, petrochemical facilities, power stations and industrial automation systems. They are built to BS 5308, PAS 5308, EN 50288-7, IEC 60332, IEC 60754.
Which standards do instrumentation cables comply with?
UE Cable instrumentation cables are manufactured and tested to BS 5308, PAS 5308, EN 50288-7, IEC 60332, IEC 60754. The exact standard for each construction is stated on its specification sheet.
What sizes and configurations are available?
83 construction families are catalogued under instrumentation cables, each offered across a range of conductor sizes and core or pair counts. Open any specification sheet for the exact conductor size, voltage, operating temperature, current rating, overall diameter and weight.
Can instrumentation cables be custom-made, and how fast is a quote?
Yes. UE Cable manufactures to customer specification — conductor, insulation, screen, armour, sheath, colour, printing and packing. Send your requirement through the inquiry list and we typically reply within 6 hours with price, lead time and test documentation.
Related Resources
You may also be interested in.
Compare nearby cable families, standards and application pages before you send an enquiry.
Fire resistant cables designed to maintain circuit integrity for emergency systems, fire alarms, life safety installations, public buildings and critical infrastructure.