Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
EN 50288-7 RE-Y(St)Y PiMF Multitriple Instrumentation Cable cable construction reference

Individual And Overall Screened

EN 50288-7 RE-Y(St)Y PiMF Multitriple Instrumentation Cable

EN 50288-7 RE-Y(St)Y PiMF Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PVC insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.

Standard
EN 50288-7
Voltage class
300/500 V or 500 V application reference
Conductor
0.5 mm², 0.75 mm², 1.0 mm², 1.5 mm² and customer-specified sizes
Insulation / jacket
PVC
Cross-section range
2 triple to 24 triple available range

Cable Type Data

Construction and applications.

Applications

EN 50288-7 RE-Y(St)Y PiMF Multitriple Instrumentation Cable is an instrumentation cable construction for multi-circuit three-wire instrumentation routes in process plants, combining PVC insulation, PVC sheath, individual pair or triple aluminium/polyester screens plus collective overall screen and a protected installation profile.

  • Process control signal transmission
  • Petrochemical and refinery instrumentation
  • Power station monitoring and control
  • DCS, PLC, marshalling cabinet and junction box wiring
  • multi-circuit three-wire instrumentation routes in process plants

Cable Construction

  • Bare or tinned annealed copper conductor, Class 1 (solid), Class 2 (stranded) or Class 5 (flexible) as specified
  • PVC insulated triples with identification to cable schedule
  • Individual pair or triple screen with drain wire where required
  • Individual pair or triple aluminium/polyester screens plus collective overall screen
  • Separator or bedding tape as required by construction
  • standard
  • PVC outer sheath with required cable marking

Specifications

Select a cable size.

Each row below is a complete specification sheet — 28 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

RE-Y(St)Y PiMF Multitriple specification references

Each row is an exact instrumentation cable cable specification sheet. Confirm sheath colour, intrinsic-safety marking, drum length and test documents before quotation.

  • Conductor classClass 1 (solid) / 2 (stranded) / 5 (flexible)
Cable referencePair / triple / core layoutConductor sizeMax DC resistance at 20 °CMutual capacitanceL/R ratioOD guideWeight guide
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-2TRIPLE-0P5MM2 2 triple 0.5 mm²2 triple0.5 mm²39.39 Ω/km75 pF/m guide25 uH/ohm9.3 mm99 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-2TRIPLE-0P75MM2 2 triple 0.75 mm²2 triple0.75 mm²26.8 Ω/km75 pF/m guide25 uH/ohm9.5 mm112 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-2TRIPLE-1P0MM2 2 triple 1.0 mm²2 triple1.0 mm²19.7 Ω/km85 pF/m guide40 uH/ohm9.7 mm126 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-2TRIPLE-1P5MM2 2 triple 1.5 mm²2 triple1.5 mm²13.43 Ω/km85 pF/m guide40 uH/ohm10.0 mm153 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-4TRIPLE-0P5MM2 4 triple 0.5 mm²4 triple0.5 mm²39.39 Ω/km75 pF/m guide25 uH/ohm10.2 mm136 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-4TRIPLE-0P75MM2 4 triple 0.75 mm²4 triple0.75 mm²26.8 Ω/km75 pF/m guide25 uH/ohm10.4 mm163 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-4TRIPLE-1P0MM2 4 triple 1.0 mm²4 triple1.0 mm²19.7 Ω/km85 pF/m guide40 uH/ohm10.6 mm190 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-4TRIPLE-1P5MM2 4 triple 1.5 mm²4 triple1.5 mm²13.43 Ω/km85 pF/m guide40 uH/ohm10.9 mm243 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-8TRIPLE-0P5MM2 8 triple 0.5 mm²8 triple0.5 mm²39.39 Ω/km75 pF/m guide25 uH/ohm11.4 mm210 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-8TRIPLE-0P75MM2 8 triple 0.75 mm²8 triple0.75 mm²26.8 Ω/km75 pF/m guide25 uH/ohm11.6 mm264 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-8TRIPLE-1P0MM2 8 triple 1.0 mm²8 triple1.0 mm²19.7 Ω/km85 pF/m guide40 uH/ohm11.8 mm317 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-8TRIPLE-1P5MM2 8 triple 1.5 mm²8 triple1.5 mm²13.43 Ω/km85 pF/m guide40 uH/ohm12.1 mm424 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-12TRIPLE-0P5MM2 12 triple 0.5 mm²12 triple0.5 mm²39.39 Ω/km75 pF/m guide25 uH/ohm12.3 mm285 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-12TRIPLE-0P75MM2 12 triple 0.75 mm²12 triple0.75 mm²26.8 Ω/km75 pF/m guide25 uH/ohm12.5 mm365 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-12TRIPLE-1P0MM2 12 triple 1.0 mm²12 triple1.0 mm²19.7 Ω/km85 pF/m guide40 uH/ohm12.7 mm445 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-12TRIPLE-1P5MM2 12 triple 1.5 mm²12 triple1.5 mm²13.43 Ω/km85 pF/m guide40 uH/ohm13.0 mm605 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-16TRIPLE-0P5MM2 16 triple 0.5 mm²16 triple0.5 mm²39.39 Ω/km75 pF/m guide25 uH/ohm13.1 mm359 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-16TRIPLE-0P75MM2 16 triple 0.75 mm²16 triple0.75 mm²26.8 Ω/km75 pF/m guide25 uH/ohm13.3 mm466 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-16TRIPLE-1P0MM2 16 triple 1.0 mm²16 triple1.0 mm²19.7 Ω/km85 pF/m guide40 uH/ohm13.5 mm572 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-16TRIPLE-1P5MM2 16 triple 1.5 mm²16 triple1.5 mm²13.43 Ω/km85 pF/m guide40 uH/ohm13.8 mm786 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-20TRIPLE-0P5MM2 20 triple 0.5 mm²20 triple0.5 mm²39.39 Ω/km75 pF/m guide25 uH/ohm13.8 mm433 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-20TRIPLE-0P75MM2 20 triple 0.75 mm²20 triple0.75 mm²26.8 Ω/km75 pF/m guide25 uH/ohm14.0 mm567 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-20TRIPLE-1P0MM2 20 triple 1.0 mm²20 triple1.0 mm²19.7 Ω/km85 pF/m guide40 uH/ohm14.2 mm700 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-20TRIPLE-1P5MM2 20 triple 1.5 mm²20 triple1.5 mm²13.43 Ω/km85 pF/m guide40 uH/ohm14.5 mm967 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-24TRIPLE-0P5MM2 24 triple 0.5 mm²24 triple0.5 mm²39.39 Ω/km75 pF/m guide25 uH/ohm14.5 mm507 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-24TRIPLE-0P75MM2 24 triple 0.75 mm²24 triple0.75 mm²26.8 Ω/km75 pF/m guide25 uH/ohm14.7 mm667 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-24TRIPLE-1P0MM2 24 triple 1.0 mm²24 triple1.0 mm²19.7 Ω/km85 pF/m guide40 uH/ohm14.9 mm828 kg/km
UEC-EN50288-7-PVC-PVC-IOS-MULTITRIPLE-24TRIPLE-1P5MM2 24 triple 1.5 mm²24 triple1.5 mm²13.43 Ω/km85 pF/m guide40 uH/ohm15.2 mm1148 kg/km
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote