Scope
Circuit integrity under fire conditions for safety-critical cable applications.
Cable Standard
IEC 60331 covers fire resistance testing for cables required to maintain circuit integrity.
Circuit integrity under fire conditions for safety-critical cable applications.
| Standard focus | Circuit integrity under fire conditions for safety-critical cable applications. |
|---|---|
| Typical applications | Emergency systems, Critical circuits |
| Related product families | Fire Resistant Cables |
| Common voltage references | 300/500 V, 450/750 V or 0.6/1 kV |
| Construction impact | Copper conductor; Mica glass fire barrier; XLPE, silicone or LSZH insulation; Optional armour |
| Datasheet requirement | Confirm construction, rating, sheath, testing reference, marking and packing before quotation |
Use these cable pages to move from the standard reference to a quote-ready construction.
BS 7846 Mica XLPE LSZH SWA Fire Resistant Power Cable is a fire resistant cable construction for critical power circuits, tunnels, airports applications, using copper conductor, mica glass fire barrier, xlpe insulation, swa armour and lszh outer sheath.
View technical data →BS 6387 CWZ Mica LSZH Fire Resistant Power Cable is a fire resistant cable construction for emergency lighting, fire pumps, smoke extraction applications, using copper conductor, mica glass fire barrier, fire resistant lszh insulation, lszh bedding and sheath and lszh outer sheath.
View technical data →BS 7629-1 Screened Fire Alarm Cable is a fire resistant cable construction for fire alarm systems, voice alarm systems, emergency lighting control applications, using copper conductor, mica fire barrier over conductor, fire resistant lszh insulation, aluminium/polyester screen and drain wire and lszh outer sheath.
View technical data →EN 50200 PH120 Fire Alarm Cable is a fire resistant cable construction for emergency circuits, fire alarm loops, public buildings applications, using copper conductor, mica fire barrier, lszh fire resistant insulation, optional foil screen and lszh outer sheath.
View technical data →IEC 60331 Mica XLPE LSZH Fire Resistant Power Cable is a fire resistant cable construction for critical feeders, emergency power, industrial safety circuits applications, using copper conductor, mica glass tape fire barrier, xlpe insulation, lszh sheath and lszh outer sheath.
View technical data →Fire Resistant Instrumentation Cable To BS 7846 is a fire resistant cable construction for fire resistant instrumentation, emergency control circuits, safety system signals applications, using copper conductor, mica fire barrier, fire resistant lszh insulation, collective metallic screen and drain wire and lszh outer sheath.
View technical data →Silicone Rubber Fire Resistant Control Cable is a fire resistant cable construction for fire safety controls, high temperature equipment, emergency control panels applications, using copper conductor, silicone rubber fire resistant insulation, silicone rubber insulation, optional braid screen and silicone or lszh sheath.
View technical data →Mineral Insulated Copper Sheathed Fire Resistant Cable is a fire resistant cable construction for fire alarm circuits, emergency lighting, oil and gas safety circuits applications, using copper conductor, magnesium oxide mineral insulation, mineral insulation, copper sheath and copper sheath with optional lszh oversheath.
View technical data →BS 5308 Armoured Instrumentation Oil And Gas Cable is an oil, gas and petrochemical cable construction for Refinery instrumentation, Petrochemical process control, Tank farm signals, with BS 5308, multipair instrumentation cable, overall aluminium/polyester screen with drain wire and steel wire armour, flame retardant or lszh option and pvc or lszh outer sheath.
View technical data →EN 50288-7 Blue LSZH Intrinsically Safe Instrumentation Cable is an oil, gas and petrochemical cable construction for Intrinsically safe loops, Process plants, Offshore instrumentation, with EN 50288-7, individual and overall screened multipair instrumentation cable, individual pair screen plus overall screen, lszh, low smoke and flame retardant and blue lszh outer sheath.
View technical data →Fire Resistant Instrumentation Mica LSZH SWA Oil And Gas Cable is an oil, gas and petrochemical cable construction for Emergency shutdown circuits, Fire and gas systems, Offshore safety loops, with IEC 60331 / EN 50288-7, mica fire barrier screened instrumentation cable, individual or overall screen with steel wire armour, circuit integrity fire resistant, lszh and low smoke and orange or blue lszh outer sheath.
View technical data →NEK 606 RFOU LV Power And Control Oil And Gas Cable is an oil, gas and petrochemical cable construction for Offshore power circuits, Topside modules, FPSO control circuits, with NEK 606, rfou flame retardant power and control cable, braid armour or offshore mechanical protection, flame retardant, low smoke and halogen free and shf2 mud resistant offshore sheath.
View technical data →NEK 606 BFOU Fire Resistant Power And Control Oil And Gas Cable is an oil, gas and petrochemical cable construction for Emergency power circuits, Offshore safety systems, Fire pump control, with NEK 606, bfou fire resistant power and control cable, braid armour or offshore mechanical protection, circuit integrity fire resistant, low smoke and halogen free and shf2 mud resistant offshore sheath.
View technical data →NEK 606 RFOU Medium Voltage Offshore Oil And Gas Cable is an oil, gas and petrochemical cable construction for Offshore MV feeders, Drilling modules, Production platforms, with NEK 606 / IEC 60502-2, medium voltage offshore power cable, copper wire screen and braid armour, flame retardant, low smoke and halogen free and shf2 mud resistant offshore sheath.
View technical data →Offshore VFD EMC Drive Oil And Gas Cable is an oil, gas and petrochemical cable construction for Offshore VFD motors, Pump drives, Compressor drives, with NEK 606 / IEC 60502, emc screened vfd drive cable, low impedance copper tape and braid emc screen, flame retardant, low smoke and halogen free and oil and mud resistant shf2 sheath.
View technical data →Refinery LSZH Control SWA Oil And Gas Cable is an oil, gas and petrochemical cable construction for Refinery control circuits, Tank farm controls, Process skids, with IEC 60502-1 / BS 5467, multicore control cable, steel wire armour, lszh, low smoke and flame retardant and black lszh outer sheath.
View technical data →Fire And Gas Safety Circuit Oil And Gas Cable is an oil, gas and petrochemical cable construction for Fire and gas detection, Emergency alarms, Evacuation systems, with IEC 60331 / BS 7629-1, fire resistant screened alarm and safety cable, foil screen with drain wire and optional armour, circuit integrity, lszh and low smoke and red or orange lszh outer sheath.
View technical data →Offshore Communication And Fibre Oil And Gas Cable is an oil, gas and petrochemical cable construction for Offshore automation networks, Fieldbus systems, Control room links, with IEC 60794 / IEC 61158, screened data, fieldbus and optical communication cable, foil/braid screen or dielectric optical protection, lszh, low smoke and flame retardant and shf1 or lszh communication sheath.
View technical data →When using this standard for an enquiry, confirm the full cable designation, conductor size, core count, voltage rating, sheath material, installation environment, testing requirements, cable marking and packing length. Standards help define the technical baseline, but the quote details should always match the final cable specification.
| What does IEC 60331 Fire Resistant Cable affect in cable selection? | IEC 60331 Fire Resistant Cable normally affects the cable construction, application range, testing references and datasheet wording. Buyers should use the standard page together with the product page before final quotation. |
|---|---|
| Is IEC 60331 Fire Resistant Cable enough to specify a cable? | Usually no. A complete enquiry should also include conductor size, core count, voltage rating, sheath material, screening or mechanical protection, installation environment and any customer-specified approvals. |
| Which UE Cable product families relate to IEC 60331 Fire Resistant Cable? | Fire Resistant Cables |