Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
Fire And Gas Safety Circuit Oil And Gas Cable cable construction reference

Fire and gas alarm circuit cable

Fire And Gas Safety Circuit Oil And Gas Cable

Fire And Gas Safety Circuit Oil And Gas Cable is an oil, gas and petrochemical cable construction for Fire and gas detection, Emergency alarms, Evacuation systems, with IEC 60331 / BS 7629-1, fire resistant screened alarm and safety cable, foil screen with drain wire and optional armour, circuit integrity, lszh and low smoke and red or orange lszh outer sheath.

Standard
IEC 60331 / BS 7629-1
Voltage class
300/500 V, 0.6/1 kV
Conductor
1.0 mm², 1.5 mm², 2.5 mm²
Insulation / jacket
Red or orange LSZH outer sheath

Cable Type Data

Construction and applications.

Applications

Fire And Gas Safety Circuit Oil And Gas Cable is an oil, gas and petrochemical cable construction for Fire and gas detection, Emergency alarms, Evacuation systems, with IEC 60331 / BS 7629-1, fire resistant screened alarm and safety cable, foil screen with drain wire and optional armour, circuit integrity, lszh and low smoke and red or orange lszh outer sheath.

  • Fire and gas detection
  • Emergency alarms
  • Evacuation systems
  • Safety instrumented systems

Cable Construction

  • Fire resistant screened alarm and safety cable
  • Plain or tinned copper conductor, or optical fibre element where applicable
  • Circuit insulation and identification for oil, gas and petrochemical cable schedules
  • Foil screen with drain wire and optional armour
  • Circuit integrity, LSZH and low smoke
  • Red or orange LSZH outer sheath for fire and gas detection, emergency alarm and evacuation circuits

Specifications

Select a cable size.

Each row below is a complete specification sheet — 24 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

Fire And Gas Safety Circuit specification references

Each row is an exact cable specification sheet. Confirm hazardous-area route, cable schedule, fire survival level, oil/mud exposure, gland/accessory package, marking and drum length before quotation.

  • Service packageFire and gas alarm and safety package
  • StandardIEC 60331 / BS 7629-1
  • Cable designFire resistant screened alarm and safety cable
  • Screen / protectionFoil screen with drain wire and optional armour
  • Fire and safety ratingCircuit integrity, LSZH and low smoke
  • Oil, mud and environmentFire and gas detection, emergency alarm and evacuation circuits
  • SheathRed or orange LSZH outer sheath
Cable referenceVoltage / signal classPair / core designConductor / fibreElectrical / optical referenceOD guide
Fire And Gas Safety Circuit 300/500 V 2 core 1.0 mm² Red or orange LSZH outer sheath300/500 V2 core1.0 mm²18.1 Ω/km max20.5 mm
Fire And Gas Safety Circuit 300/500 V 2 core 1.5 mm² Red or orange LSZH outer sheath300/500 V2 core1.5 mm²12.1 Ω/km max20.9 mm
Fire And Gas Safety Circuit 300/500 V 2 core 2.5 mm² Red or orange LSZH outer sheath300/500 V2 core2.5 mm²7.41 Ω/km max21.4 mm
Fire And Gas Safety Circuit 300/500 V 4 core 1.0 mm² Red or orange LSZH outer sheath300/500 V4 core1.0 mm²18.1 Ω/km max21.3 mm
Fire And Gas Safety Circuit 300/500 V 4 core 1.5 mm² Red or orange LSZH outer sheath300/500 V4 core1.5 mm²12.1 Ω/km max21.7 mm
Fire And Gas Safety Circuit 300/500 V 4 core 2.5 mm² Red or orange LSZH outer sheath300/500 V4 core2.5 mm²7.41 Ω/km max22.2 mm
Fire And Gas Safety Circuit 300/500 V 2 pair 1.0 mm² Red or orange LSZH outer sheath300/500 V2 pair1.0 mm²18.1 Ω/km max18.3 mm
Fire And Gas Safety Circuit 300/500 V 2 pair 1.5 mm² Red or orange LSZH outer sheath300/500 V2 pair1.5 mm²12.1 Ω/km max18.7 mm
Fire And Gas Safety Circuit 300/500 V 2 pair 2.5 mm² Red or orange LSZH outer sheath300/500 V2 pair2.5 mm²7.41 Ω/km max19.2 mm
Fire And Gas Safety Circuit 300/500 V 4 pair 1.0 mm² Red or orange LSZH outer sheath300/500 V4 pair1.0 mm²18.1 Ω/km max19.4 mm
Fire And Gas Safety Circuit 300/500 V 4 pair 1.5 mm² Red or orange LSZH outer sheath300/500 V4 pair1.5 mm²12.1 Ω/km max19.8 mm
Fire And Gas Safety Circuit 300/500 V 4 pair 2.5 mm² Red or orange LSZH outer sheath300/500 V4 pair2.5 mm²7.41 Ω/km max20.3 mm
Fire And Gas Safety Circuit 0.6/1 kV 2 core 1.0 mm² Red or orange LSZH outer sheath0.6/1 kV2 core1.0 mm²18.1 Ω/km max20.5 mm
Fire And Gas Safety Circuit 0.6/1 kV 2 core 1.5 mm² Red or orange LSZH outer sheath0.6/1 kV2 core1.5 mm²12.1 Ω/km max20.9 mm
Fire And Gas Safety Circuit 0.6/1 kV 2 core 2.5 mm² Red or orange LSZH outer sheath0.6/1 kV2 core2.5 mm²7.41 Ω/km max21.4 mm
Fire And Gas Safety Circuit 0.6/1 kV 4 core 1.0 mm² Red or orange LSZH outer sheath0.6/1 kV4 core1.0 mm²18.1 Ω/km max21.3 mm
Fire And Gas Safety Circuit 0.6/1 kV 4 core 1.5 mm² Red or orange LSZH outer sheath0.6/1 kV4 core1.5 mm²12.1 Ω/km max21.7 mm
Fire And Gas Safety Circuit 0.6/1 kV 4 core 2.5 mm² Red or orange LSZH outer sheath0.6/1 kV4 core2.5 mm²7.41 Ω/km max22.2 mm
Fire And Gas Safety Circuit 0.6/1 kV 2 pair 1.0 mm² Red or orange LSZH outer sheath0.6/1 kV2 pair1.0 mm²18.1 Ω/km max18.3 mm
Fire And Gas Safety Circuit 0.6/1 kV 2 pair 1.5 mm² Red or orange LSZH outer sheath0.6/1 kV2 pair1.5 mm²12.1 Ω/km max18.7 mm
Fire And Gas Safety Circuit 0.6/1 kV 2 pair 2.5 mm² Red or orange LSZH outer sheath0.6/1 kV2 pair2.5 mm²7.41 Ω/km max19.2 mm
Fire And Gas Safety Circuit 0.6/1 kV 4 pair 1.0 mm² Red or orange LSZH outer sheath0.6/1 kV4 pair1.0 mm²18.1 Ω/km max19.4 mm
Fire And Gas Safety Circuit 0.6/1 kV 4 pair 1.5 mm² Red or orange LSZH outer sheath0.6/1 kV4 pair1.5 mm²12.1 Ω/km max19.8 mm
Fire And Gas Safety Circuit 0.6/1 kV 4 pair 2.5 mm² Red or orange LSZH outer sheath0.6/1 kV4 pair2.5 mm²7.41 Ω/km max20.3 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote