Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
NEK 606 RFOU Medium Voltage Offshore Oil And Gas Cable cable construction reference

Offshore medium-voltage cable

NEK 606 RFOU Medium Voltage Offshore Oil And Gas Cable

NEK 606 RFOU Medium Voltage Offshore Oil And Gas Cable is an oil, gas and petrochemical cable construction for Offshore MV feeders, Drilling modules, Production platforms, with NEK 606 / IEC 60502-2, medium voltage offshore power cable, copper wire screen and braid armour, flame retardant, low smoke and halogen free and shf2 mud resistant offshore sheath.

Standard
NEK 606 / IEC 60502-2
Voltage class
3.6/6 kV, 6/10 kV, 8.7/15 kV
Conductor
25 mm², 35 mm², 50 mm², 70 mm², 95 mm²
Insulation / jacket
SHF2 mud resistant offshore sheath

Cable Type Data

Construction and applications.

Applications

NEK 606 RFOU Medium Voltage Offshore Oil And Gas Cable is an oil, gas and petrochemical cable construction for Offshore MV feeders, Drilling modules, Production platforms, with NEK 606 / IEC 60502-2, medium voltage offshore power cable, copper wire screen and braid armour, flame retardant, low smoke and halogen free and shf2 mud resistant offshore sheath.

  • Offshore MV feeders
  • Drilling modules
  • Production platforms
  • Utility power distribution

Cable Construction

  • Medium voltage offshore power cable
  • Plain or tinned copper conductor, or optical fibre element where applicable
  • Circuit insulation and identification for oil, gas and petrochemical cable schedules
  • Copper wire screen and braid armour
  • Flame retardant, low smoke and halogen free
  • SHF2 mud resistant offshore sheath for offshore power distribution, drilling and production modules

Specifications

Select a cable size.

Each row below is a complete specification sheet — 15 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

RFOU Medium Voltage Offshore specification references

Each row is an exact cable specification sheet. Confirm hazardous-area route, cable schedule, fire survival level, oil/mud exposure, gland/accessory package, marking and drum length before quotation.

  • Service packageOffshore medium-voltage distribution package
  • StandardNEK 606 / IEC 60502-2
  • Cable designMedium voltage offshore power cable
  • Pair / core design3 core
  • Screen / protectionCopper wire screen and braid armour
  • Fire and safety ratingFlame retardant, low smoke and halogen free
  • Oil, mud and environmentOffshore power distribution, drilling and production modules
  • SheathSHF2 mud resistant offshore sheath
Cable referenceVoltage / signal classConductor / fibreElectrical / optical referenceOD guide
RFOU Medium Voltage Offshore 3.6/6 kV 3 core 25 mm² SHF2 mud resistant offshore sheath3.6/6 kV25 mm²0.727 Ω/km max27.9 mm
RFOU Medium Voltage Offshore 3.6/6 kV 3 core 35 mm² SHF2 mud resistant offshore sheath3.6/6 kV35 mm²0.524 Ω/km max29.4 mm
RFOU Medium Voltage Offshore 3.6/6 kV 3 core 50 mm² SHF2 mud resistant offshore sheath3.6/6 kV50 mm²0.387 Ω/km max31.3 mm
RFOU Medium Voltage Offshore 3.6/6 kV 3 core 70 mm² SHF2 mud resistant offshore sheath3.6/6 kV70 mm²0.268 Ω/km max33.3 mm
RFOU Medium Voltage Offshore 3.6/6 kV 3 core 95 mm² SHF2 mud resistant offshore sheath3.6/6 kV95 mm²0.193 Ω/km max35.5 mm
RFOU Medium Voltage Offshore 6/10 kV 3 core 25 mm² SHF2 mud resistant offshore sheath6/10 kV25 mm²Conductor resistance, screen fault rating and partial discharge test reference49.9 mm
RFOU Medium Voltage Offshore 6/10 kV 3 core 35 mm² SHF2 mud resistant offshore sheath6/10 kV35 mm²Conductor resistance, screen fault rating and partial discharge test reference52.9 mm
RFOU Medium Voltage Offshore 6/10 kV 3 core 50 mm² SHF2 mud resistant offshore sheath6/10 kV50 mm²Conductor resistance, screen fault rating and partial discharge test reference56.6 mm
RFOU Medium Voltage Offshore 6/10 kV 3 core 70 mm² SHF2 mud resistant offshore sheath6/10 kV70 mm²Conductor resistance, screen fault rating and partial discharge test reference60.7 mm
RFOU Medium Voltage Offshore 6/10 kV 3 core 95 mm² SHF2 mud resistant offshore sheath6/10 kV95 mm²Conductor resistance, screen fault rating and partial discharge test reference65.1 mm
RFOU Medium Voltage Offshore 8.7/15 kV 3 core 25 mm² SHF2 mud resistant offshore sheath8.7/15 kV25 mm²Conductor resistance, screen fault rating and partial discharge test reference49.9 mm
RFOU Medium Voltage Offshore 8.7/15 kV 3 core 35 mm² SHF2 mud resistant offshore sheath8.7/15 kV35 mm²Conductor resistance, screen fault rating and partial discharge test reference52.9 mm
RFOU Medium Voltage Offshore 8.7/15 kV 3 core 50 mm² SHF2 mud resistant offshore sheath8.7/15 kV50 mm²Conductor resistance, screen fault rating and partial discharge test reference56.6 mm
RFOU Medium Voltage Offshore 8.7/15 kV 3 core 70 mm² SHF2 mud resistant offshore sheath8.7/15 kV70 mm²Conductor resistance, screen fault rating and partial discharge test reference60.7 mm
RFOU Medium Voltage Offshore 8.7/15 kV 3 core 95 mm² SHF2 mud resistant offshore sheath8.7/15 kV95 mm²Conductor resistance, screen fault rating and partial discharge test reference65.1 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote