Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价

Cable Standard

CSA C22.2 No. 131 TECK 90 Cable

Canadian standard for TECK 90 armoured power cable with aluminium interlocked armour for industrial, mining and oil and gas installations.

Mining / Oil and gas 3 related product families 9 cable references
Applications3Mining, Oil and gas, Industrial plants
Products3Armoured Cables, Low Voltage Power Cables
Cable Types9Specific cable construction pages
QuoteDetailsConstruction, marking, testing and packing notes

Scope

Armoured low and medium voltage power cable for Canadian and North American industrial projects.

Applications

  • Mining
  • Oil and gas
  • Industrial plants

Standard Selection Data

Standard focusArmoured low and medium voltage power cable for Canadian and North American industrial projects.
Typical applicationsMining, Oil and gas, Industrial plants
Related product familiesArmoured Cables, Low Voltage Power Cables, Medium Voltage Cables
Common voltage references0.6/1 kV, 6.35/11 kV and 19/33 kV armoured references; 0.6/1 kV; 3.6/6 kV to 19/33 kV and customer-specified
Construction impactCopper or aluminium conductor; XLPE, PVC or fire resistant insulation system; PVC or LSZH bedding below the armour; SWA for multicore, AWA for single-core AC circuits, steel tape armour or control-cable armour where required
Datasheet requirementConfirm construction, rating, sheath, testing reference, marking and packing before quotation

Cable Construction Impact

  • Copper or aluminium conductor
  • XLPE, PVC or fire resistant insulation system
  • PVC or LSZH bedding below the armour
  • SWA for multicore, AWA for single-core AC circuits, steel tape armour or control-cable armour where required
  • PVC, LSZH or fire resistant outer sheath
  • XLPE or PVC insulation
  • Optional bedding
  • SWA or AWA armour
  • PVC or LSZH outer sheath
  • Conductor screen

Cables Using This Standard

Use these cable pages to move from the standard reference to a quote-ready construction.

Low-voltage SWA armoured cable

BS 5467 XLPE SWA PVC Multicore Armoured Cable

BS 5467 XLPE SWA PVC Multicore Armoured Cable is an armoured cable construction for mains distribution, industrial wiring, direct burial, using copper or aluminium conductor, xlpe, pvc bedding, steel wire armour for multicore cable and pvc outer sheath.

  • BS 5467 XLPE/SWA/PVC
  • BS 5467
  • 0.6/1 kV
View technical data →
BS 5467 XLPE AWA PVC Single Core Armoured Cable Low-voltage AWA single core cable

BS 5467 XLPE AWA PVC Single Core Armoured Cable

BS 5467 XLPE AWA PVC Single Core Armoured Cable is an armoured cable construction for single-core ac feeders, industrial distribution, cable ducts, using copper or aluminium conductor, xlpe, pvc bedding, aluminium wire armour for single core cable and pvc outer sheath.

  • BS 5467 XLPE/AWA/PVC
  • BS 5467
  • 0.6/1 kV
View technical data →
Low smoke SWA armoured cable

BS 6724 XLPE SWA LSZH Multicore Armoured Cable

BS 6724 XLPE SWA LSZH Multicore Armoured Cable is an armoured cable construction for public buildings, transport terminals, data centers, using copper or aluminium conductor, xlpe, lszh bedding, steel wire armour for multicore cable and lszh outer sheath.

  • BS 6724 XLPE/SWA/LSZH
  • BS 6724
  • 0.6/1 kV
View technical data →
0.6/1 kV power cable

IEC 60502-1 XLPE PVC Low Voltage Power Cable

IEC 60502-1 XLPE PVC Low Voltage Power Cable is a specific low-voltage power cable construction for power distribution, industrial plants, building feeders applications, using copper or aluminium conductor, xlpe insulation and pvc outer sheath.

  • IEC 60502-1 XLPE/PVC
  • IEC 60502-1
  • 0.6/1 kV
View technical data →
Armoured LV power cable

IEC 60502-1 XLPE SWA PVC Armoured Power Cable

IEC 60502-1 XLPE SWA PVC Armoured Power Cable is a specific low-voltage power cable construction for direct burial, industrial plants, outdoor feeders applications, using copper or aluminium conductor, xlpe insulation, steel wire armour for multicore cable and pvc outer sheath.

  • IEC 60502-1 XLPE/SWA/PVC
  • IEC 60502-1
  • 0.6/1 kV
View technical data →
British standard armoured cable

BS 5467 XLPE SWA PVC Power Cable

BS 5467 XLPE SWA PVC Power Cable is a specific low-voltage power cable construction for building services, industrial distribution, utilities applications, using plain copper or aluminium conductor, xlpe insulation, steel wire armour for multicore cable and pvc outer sheath.

  • BS 5467 XLPE/SWA/PVC
  • BS 5467
  • 0.6/1 kV
View technical data →
IEC 60502-2 Single Core XLPE PVC MV Cable Single core MV cable

IEC 60502-2 Single Core XLPE PVC MV Cable

IEC 60502-2 Single Core XLPE PVC MV Cable is a specific medium-voltage cable construction for utility distribution, substations, industrial feeders applications, using copper or aluminium conductor, xlpe insulation, copper wire or copper tape screen, non-magnetic protection where required and pvc outer sheath.

  • IEC 60502-2 single core MV cable
  • IEC 60502-2
  • 3.6/6 kV to 18/30 kV
View technical data →
Three core armoured MV cable

IEC 60502-2 Three Core XLPE SWA PVC MV Cable

IEC 60502-2 Three Core XLPE SWA PVC MV Cable is a specific medium-voltage cable construction for utility feeders, industrial distribution, direct burial applications, using copper or aluminium conductor, xlpe insulation, copper tape or copper wire screen, steel wire armour for three-core cable and pvc outer sheath.

  • IEC 60502-2 three core XLPE/SWA/PVC
  • IEC 60502-2
  • 3.6/6 kV to 18/30 kV
View technical data →
BS 6622 XLPE AWA SWA PVC MV Cable British standard PVC MV cable

BS 6622 XLPE AWA SWA PVC MV Cable

BS 6622 XLPE AWA SWA PVC MV Cable is a specific medium-voltage cable construction for uk-style mv distribution, substations, industrial feeders applications, using copper or aluminium conductor, xlpe insulation, copper tape or copper wire screen, awa for single core, swa for three core and pvc outer sheath.

  • BS 6622 XLPE/AWA/SWA/PVC
  • BS 6622
  • 3.6/6 kV to 18/30 kV
View technical data →

Procurement Notes

When using this standard for an enquiry, confirm the full cable designation, conductor size, core count, voltage rating, sheath material, installation environment, testing requirements, cable marking and packing length. Standards help define the technical baseline, but the quote details should always match the final cable specification.

Quote Details

  • Cable type and standard reference
  • Conductor material, size and class
  • Core count, pair count or fiber count
  • Voltage rating and operating environment
  • Screening, armour, fire performance and sheath material
  • Cable marking, drum length, packing and delivery requirements

FAQ

What does CSA C22.2 No. 131 TECK 90 Cable affect in cable selection?CSA C22.2 No. 131 TECK 90 Cable normally affects the cable construction, application range, testing references and datasheet wording. Buyers should use the standard page together with the product page before final quotation.
Is CSA C22.2 No. 131 TECK 90 Cable enough to specify a cable?Usually no. A complete enquiry should also include conductor size, core count, voltage rating, sheath material, screening or mechanical protection, installation environment and any customer-specified approvals.
Which UE Cable product families relate to CSA C22.2 No. 131 TECK 90 Cable?Armoured Cables, Low Voltage Power Cables, Medium Voltage Cables