Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价

Industrial tray cable

Tray Cables

Tray cables for PLTC, ITC, TC, TC-ER, VFD, WTTC, exposed-run, direct-burial, heavy-duty and continuous-flex industrial power, control and signal circuits.

Tray Cables
Cable construction Tray Cables Technical reference for cable construction, sheath finish, screening and cross-section review.
Applications8Cable trays, Industrial plants, Process control, Power and signal circuits
Standards6UL 13, UL 2250, UL 1277, UL 1685, CSA FT4, NFPA 79
Cable Types10Cable construction pages with exact specification sheets
Specifications218Individual cable specification sheets

Application And Description

Tray cables for PLTC, ITC, TC, TC-ER, VFD, WTTC, exposed-run, direct-burial, heavy-duty and continuous-flex industrial power, control and signal circuits.

  • Cable trays
  • Industrial plants
  • Process control
  • Power and signal circuits
  • Machine tools
  • Wind turbines
  • VFD motor feeds
  • Outdoor direct burial

Cable Construction

  • Stranded copper conductor
  • PVC nylon, XLPE, XHHW-2, TPE or VFD insulation
  • Optional foil, braid or combination screen
  • PVC, TPE, sunlight-resistant or direct-burial tray jacket

Standards And References

  • UL 13
  • UL 2250
  • UL 1277
  • UL 1685
  • CSA FT4
  • NFPA 79

Tray Cable Selection Data

Voltage rating300 V PLTC/ITC, 600 V TC/TC-ER and 600 V / 1000 V VFD or WTTC references
Cable typePLTC, ITC, TC, TC-ER, shielded tray, VFD tray, WTTC, heavy-duty TPE, continuous-flex or direct-burial tray cable
ConductorStranded, fine stranded or extra fine stranded copper
InsulationPVC nylon, XLPE, XHHW-2, TPE or VFD insulation systems
JacketPVC, TPE, sunlight-resistant, oil-resistant, exposed-run or direct-burial tray jacket
ScreeningFoil, braid, individual/overall screen or VFD shield and symmetrical grounds
Key dataCircuit type, core/pair design, AWG/mm2 size, max DC resistance at 20 °C, OD guide and cable weight
InstallationCable tray, exposed run, raceway, conduit, outdoor, direct burial and industrial plant wiring

Find The Exact Cable Size

Open a cable construction page, then select the voltage, conductor material, core layout and cross-section row that matches your enquiry. Each row opens a cable specification sheet for quote preparation.

Tray Cable Type And Rating Options

Tray cable pages are organised by PLTC, ITC, TC, TC-ER, VFD, WTTC, exposed-run, direct-burial, heavy-duty and continuous-flex duty. Open a cable page to compare voltage, circuit type, core or pair design, shield, jacket rating, OD and weight.

Power-limited tray cable

PLTC 300 V Signal Tray Cable

PLTC 300 V Signal Tray Cable is a tray cable construction for signal tray circuits, alarm systems, intercom systems, using stranded bare copper conductor, pvc insulation, aluminium polyester foil screen with drain wire and flame retardant pvc tray jacket.

  • PLTC
  • UL 13
  • 300 V
  • 90 °C dry / 75 °C wet guide
View technical data →
Instrumentation tray cable

ITC Instrumentation Tray Cable

ITC Instrumentation Tray Cable is a tray cable construction for instrumentation signals, process control, analogue signals, using stranded bare copper conductor, pvc nylon instrumentation insulation, individual and overall aluminium polyester screen with drain wire and sunlight resistant pvc tray jacket.

  • ITC
  • UL 2250
  • 300 V
  • 90 °C dry / 75 °C wet guide
View technical data →
Type TC tray power and control cable

UL 1277 Type TC Power Control Tray Cable

UL 1277 Type TC Power Control Tray Cable is a tray cable construction for power control circuits, industrial plants, manufacturing lines, using stranded bare copper conductor, pvc nylon insulation and oil and sunlight resistant pvc tray jacket.

  • Type TC
  • UL 1277
  • 600 V
  • 90 °C dry / 75 °C wet guide
View technical data →
Tray cable exposed-run construction

TC-ER Exposed Run Tray Cable

TC-ER Exposed Run Tray Cable is a tray cable construction for industrial machinery, plant engineering, cable tray exposed runs, using fine stranded bare copper conductor, pvc nylon insulation and oil, sunlight and crush resistant pvc tray jacket.

  • TC-ER
  • UL 1277 TC-ER
  • 600 V
  • 90 °C dry / 75 °C wet guide
View technical data →
Shielded tray control cable

Shielded TC-ER Tray Control Cable

Shielded TC-ER Tray Control Cable is a tray cable construction for shielded controls, machine tools, process equipment, using fine stranded bare copper conductor, pvc nylon insulation, overall foil and tinned copper braid shield and oil and sunlight resistant pvc tray jacket.

  • TC-ER shielded
  • UL 1277 TC-ER
  • 600 V
  • 90 °C dry / 75 °C wet guide
View technical data →
VFD tray motor cable

Tray Rated VFD Cable

Tray Rated VFD Cable is a tray cable construction for vfd drives, motor feeds, industrial automation, using fine stranded bare copper conductor, xlpe or pvc nylon vfd insulation, overall copper tape or braid shield with symmetrical grounds and oil and sunlight resistant pvc tray jacket.

  • VFD tray cable
  • UL 1277 TC-ER / WTTC reference
  • 600 V / 1000 V
  • 90 °C dry / 75 °C wet guide
View technical data →
Wind turbine tray cable

WTTC Wind Turbine Tray Cable

WTTC Wind Turbine Tray Cable is a tray cable construction for wind turbines, nacelle wiring, tower tray routes, using fine stranded bare copper conductor, pvc nylon or tpe insulation and oil, sunlight and torsion resistant tray jacket.

  • WTTC
  • UL WTTC / TC-ER reference
  • 600 V / 1000 V
  • 90 °C to 105 °C guide
View technical data →
Heavy-duty TPE tray cable

Heavy Duty TPE Tray Cable

Heavy Duty TPE Tray Cable is a tray cable construction for heavy machinery, assembly lines, processing equipment, using fine stranded bare copper conductor, tpe or pvc nylon insulation and heavy-duty oil and sunlight resistant tpe tray jacket.

  • TRAY HD TPE
  • UL 1277 TC-ER
  • 600 V
  • 105 °C guide
View technical data →
Continuous-flex tray cable

Continuous Flex Tray Cable

Continuous Flex Tray Cable is a tray cable construction for moving machinery, cable carriers, automated lines, using extra fine stranded bare copper conductor, tpe or pvc nylon flex insulation and high-flex oil and sunlight resistant tray jacket.

  • TR 600 Auto
  • UL TC-ER / WTTC reference
  • 600 V
  • 105 °C guide
View technical data →
Outdoor and direct burial tray cable

Direct Burial Sunlight Resistant Tray Cable

Direct Burial Sunlight Resistant Tray Cable is a tray cable construction for outdoor tray, direct burial, petrochemical plants, using stranded bare copper conductor, xhhw-2 or pvc nylon insulation and sunlight, oil and direct-burial rated pvc jacket.

  • Direct burial tray cable
  • UL 1277
  • 600 V
  • 90 °C dry / 75 °C wet guide
View technical data →

Available Options

  • PLTC signal tray cable
  • ITC instrumentation tray cable
  • UL 1277 Type TC cable
  • TC-ER exposed run cable
  • Shielded tray control cable
  • Tray-rated VFD cable
  • WTTC wind turbine tray cable
  • Heavy-duty TPE tray cable
  • Continuous-flex tray cable
  • Direct burial tray cable

FAQ

Tray Cables — common questions

What are tray cables?

Tray cables for PLTC, ITC, TC, TC-ER, VFD, WTTC, exposed-run, direct-burial, heavy-duty and continuous-flex industrial power, control and signal circuits. They are built to UL 13, UL 2250, UL 1277, UL 1685, CSA FT4, NFPA 79.

Which standards do tray cables comply with?

UE Cable tray cables are manufactured and tested to UL 13, UL 2250, UL 1277, UL 1685, CSA FT4, NFPA 79. The exact standard for each construction is stated on its specification sheet.

What sizes and configurations are available?

10 construction families are catalogued under tray cables, each offered across a range of conductor sizes and core or pair counts. Open any specification sheet for the exact conductor size, voltage, operating temperature, current rating, overall diameter and weight.

Can tray cables be custom-made, and how fast is a quote?

Yes. UE Cable manufactures to customer specification — conductor, insulation, screen, armour, sheath, colour, printing and packing. Send your requirement through the inquiry list and we typically reply within 6 hours with price, lead time and test documentation.