Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
TC-ER Exposed Run Tray Cable cable construction reference

Tray cable exposed-run construction

TC-ER Exposed Run Tray Cable

TC-ER Exposed Run Tray Cable is a tray cable construction for industrial machinery, plant engineering, cable tray exposed runs, using fine stranded bare copper conductor, pvc nylon insulation and oil, sunlight and crush resistant pvc tray jacket.

Standard
UL 1277 TC-ER
Voltage class
600 V
Temperature class
90 °C dry / 75 °C wet guide
Conductor
Fine stranded bare copper conductor
Insulation / jacket
Oil, sunlight and crush resistant PVC tray jacket

Cable Type Data

Construction and applications.

Applications

TC-ER Exposed Run Tray Cable is a tray cable construction for industrial machinery, plant engineering, cable tray exposed runs, using fine stranded bare copper conductor, pvc nylon insulation and oil, sunlight and crush resistant pvc tray jacket.

  • Industrial machinery
  • Plant engineering
  • Cable tray exposed runs
  • Control panels

Cable Construction

  • Fine stranded bare copper conductor
  • PVC nylon insulation
  • Oil, sunlight and crush resistant PVC tray jacket

Specifications

Select a cable size.

Each row below is a complete specification sheet — 28 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

TC-ER exposed-run tray cable references

Each row is an exact tray cable cable specification sheet. Shared UL/CSA rating, jacket and installation data are listed above.

  • Tray cable dutyExposed-run power and control tray
  • Circuit typePower and control
  • Voltage class600 V
Cable referenceCore / pair designConductor sizeMax DC resistance at 20 °COD guide
TC-ER 600 V Exposed-run power and control tray Power and control 3 core 18 AWG / 0.82 mm²3 core18 AWG / 0.82 mm²22.6 Ω/km12.2 mm
TC-ER 600 V Exposed-run power and control tray Power and control 3 core 16 AWG / 1.31 mm²3 core16 AWG / 1.31 mm²14.1 Ω/km12.6 mm
TC-ER 600 V Exposed-run power and control tray Power and control 3 core 14 AWG / 2.08 mm²3 core14 AWG / 2.08 mm²8.89 Ω/km13.1 mm
TC-ER 600 V Exposed-run power and control tray Power and control 3 core 12 AWG / 3.31 mm²3 core12 AWG / 3.31 mm²5.59 Ω/km13.7 mm
TC-ER 600 V Exposed-run power and control tray Power and control 4 core 18 AWG / 0.82 mm²4 core18 AWG / 0.82 mm²22.6 Ω/km12.6 mm
TC-ER 600 V Exposed-run power and control tray Power and control 4 core 16 AWG / 1.31 mm²4 core16 AWG / 1.31 mm²14.1 Ω/km13.0 mm
TC-ER 600 V Exposed-run power and control tray Power and control 4 core 14 AWG / 2.08 mm²4 core14 AWG / 2.08 mm²8.89 Ω/km13.6 mm
TC-ER 600 V Exposed-run power and control tray Power and control 4 core 12 AWG / 3.31 mm²4 core12 AWG / 3.31 mm²5.59 Ω/km14.2 mm
TC-ER 600 V Exposed-run power and control tray Power and control 5 core 18 AWG / 0.82 mm²5 core18 AWG / 0.82 mm²22.6 Ω/km13.1 mm
TC-ER 600 V Exposed-run power and control tray Power and control 5 core 16 AWG / 1.31 mm²5 core16 AWG / 1.31 mm²14.1 Ω/km13.5 mm
TC-ER 600 V Exposed-run power and control tray Power and control 5 core 14 AWG / 2.08 mm²5 core14 AWG / 2.08 mm²8.89 Ω/km14.0 mm
TC-ER 600 V Exposed-run power and control tray Power and control 5 core 12 AWG / 3.31 mm²5 core12 AWG / 3.31 mm²5.59 Ω/km14.6 mm
TC-ER 600 V Exposed-run power and control tray Power and control 7 core 18 AWG / 0.82 mm²7 core18 AWG / 0.82 mm²22.6 Ω/km13.8 mm
TC-ER 600 V Exposed-run power and control tray Power and control 7 core 16 AWG / 1.31 mm²7 core16 AWG / 1.31 mm²14.1 Ω/km14.2 mm
TC-ER 600 V Exposed-run power and control tray Power and control 7 core 14 AWG / 2.08 mm²7 core14 AWG / 2.08 mm²8.89 Ω/km14.7 mm
TC-ER 600 V Exposed-run power and control tray Power and control 7 core 12 AWG / 3.31 mm²7 core12 AWG / 3.31 mm²5.59 Ω/km15.3 mm
TC-ER 600 V Exposed-run power and control tray Power and control 12 core 18 AWG / 0.82 mm²12 core18 AWG / 0.82 mm²22.6 Ω/km15.2 mm
TC-ER 600 V Exposed-run power and control tray Power and control 12 core 16 AWG / 1.31 mm²12 core16 AWG / 1.31 mm²14.1 Ω/km15.6 mm
TC-ER 600 V Exposed-run power and control tray Power and control 12 core 14 AWG / 2.08 mm²12 core14 AWG / 2.08 mm²8.89 Ω/km16.1 mm
TC-ER 600 V Exposed-run power and control tray Power and control 12 core 12 AWG / 3.31 mm²12 core12 AWG / 3.31 mm²5.59 Ω/km16.8 mm
TC-ER 600 V Exposed-run power and control tray Power and control 18 core 18 AWG / 0.82 mm²18 core18 AWG / 0.82 mm²22.6 Ω/km16.6 mm
TC-ER 600 V Exposed-run power and control tray Power and control 18 core 16 AWG / 1.31 mm²18 core16 AWG / 1.31 mm²14.1 Ω/km17.0 mm
TC-ER 600 V Exposed-run power and control tray Power and control 18 core 14 AWG / 2.08 mm²18 core14 AWG / 2.08 mm²8.89 Ω/km17.5 mm
TC-ER 600 V Exposed-run power and control tray Power and control 18 core 12 AWG / 3.31 mm²18 core12 AWG / 3.31 mm²5.59 Ω/km18.1 mm
TC-ER 600 V Exposed-run power and control tray Power and control 25 core 18 AWG / 0.82 mm²25 core18 AWG / 0.82 mm²22.6 Ω/km17.9 mm
TC-ER 600 V Exposed-run power and control tray Power and control 25 core 16 AWG / 1.31 mm²25 core16 AWG / 1.31 mm²14.1 Ω/km18.3 mm
TC-ER 600 V Exposed-run power and control tray Power and control 25 core 14 AWG / 2.08 mm²25 core14 AWG / 2.08 mm²8.89 Ω/km18.8 mm
TC-ER 600 V Exposed-run power and control tray Power and control 25 core 12 AWG / 3.31 mm²25 core12 AWG / 3.31 mm²5.59 Ω/km19.4 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote