Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价

Model Detail

EN 50264 rolling stock cable

EN 50264 rolling stock cable is a model reference within the Rolling Stock Cables family for train wiring, metro vehicles, onboard control applications. This model page summarizes application, construction, parameters, standards and inquiry information for export buyers.

EN 50264 rolling stock cable
Cable construction EN 50264 rolling stock cable Technical reference for cable construction, sheath finish, screening and cross-section review.

Application And Operating Environment

EN 50264 rolling stock cable is a model reference within the Rolling Stock Cables family for train wiring, metro vehicles, onboard control applications. This model page summarizes application, construction, parameters, standards and inquiry information for export buyers.

  • Train wiring
  • Metro vehicles
  • Onboard control
  • Rail data systems

Standards And Application References

  • EN 50264
  • EN 50306
  • EN 45545

Specification Path

  • Open the closest construction page
  • Compare the shared material, voltage and construction data above the matrix
  • Select the exact row by size, core or pair layout and electrical parameters
  • Review the cable specification sheet before requesting a quote

Cable Construction

  • Flexible copper conductor
  • Thin-wall or standard rail insulation
  • Screened signal and data options
  • LSZH rail-approved sheath

Technical Characteristics

Product familyRolling Stock Cables
Model referenceEN 50264 rolling stock cable
Voltage ratingSignal-level, 300/500 V, 0.6/1 kV and customer-specified
ConductorFlexible tinned or plain copper conductor
InsulationRail-approved cross-linked or elastomeric insulation
Sheath or jacketTo be confirmed by cable schedule
StandardsEN 50264, EN 50306, EN 45545

Ordering Notes

For quotation, confirm conductor size, core count, voltage rating, sheath material, screening or mechanical protection requirement, standard reference, cable marking, packing length and target delivery schedule.

Matching Cable Type Pages

EN 50264-3-1 Single Core Rolling Stock Cable 600 V Standard wall single-core rail vehicle cable

EN 50264-3-1 Single Core Rolling Stock Cable 600 V

EN 50264-3-1 Single Core Rolling Stock Cable 600 V is a rolling stock cable construction for control cabinets, auxiliary circuits, driver desks, using class 5 tinned copper conductor, electron-beam cross-linked halogen-free insulation and insulation-only rolling stock single core outer sheath.

  • EN 50264 single core 600 V
  • EN 50264-3-1
  • 0.6/1 kV
  • -45 °C to +120 °C fixed guide
View technical data →
EN 50264-3-1 Single Core Rolling Stock Cable 1.8/3 kV Higher-voltage single-core rail vehicle cable

EN 50264-3-1 Single Core Rolling Stock Cable 1.8/3 kV

EN 50264-3-1 Single Core Rolling Stock Cable 1.8/3 kV is a rolling stock cable construction for converters, main power wiring, distribution boxes, using class 5 tinned copper conductor, electron-beam cross-linked halogen-free insulation and insulation-only rolling stock single core outer sheath.

  • EN 50264 single core 1.8/3 kV
  • EN 50264-3-1
  • 1.8/3 kV
  • -45 °C to +120 °C fixed guide
View technical data →
Standard wall multicore control cable

EN 50264-3-2 Multicore Rolling Stock Control Cable

EN 50264-3-2 Multicore Rolling Stock Control Cable is a rolling stock cable construction for train control, auxiliary systems, switchboards, using class 5 tinned copper conductor, cross-linked halogen-free core insulation and halogen-free rolling stock outer sheath.

  • EN 50264 multicore control cable
  • EN 50264-3-2
  • 300/500 V or 0.6/1 kV
  • -40 °C to +120 °C fixed guide
View technical data →
Screened standard wall multicore cable

EN 50264-3-2 Screened Multicore Rolling Stock Cable

EN 50264-3-2 Screened Multicore Rolling Stock Cable is a rolling stock cable construction for emc-sensitive control, vehicle electronics, auxiliary systems, using class 5 tinned copper conductor, cross-linked halogen-free core insulation, overall tinned copper braid screen and halogen-free rolling stock outer sheath.

  • EN 50264 screened multicore
  • EN 50264-3-2
  • 300/500 V or 0.6/1 kV
  • -40 °C to +120 °C fixed guide
View technical data →
EN 50306-2 Thin Wall Single Core Rolling Stock Cable Thin wall single-core train wire

EN 50306-2 Thin Wall Single Core Rolling Stock Cable

EN 50306-2 Thin Wall Single Core Rolling Stock Cable is a rolling stock cable construction for compact harnesses, control panels, vehicle wiring, using class 5 tinned copper conductor, thin wall halogen-free elastomer insulation and insulation-only thin wall rolling stock wire outer sheath.

  • EN 50306 thin wall single core
  • EN 50306-2
  • 300 V
  • 90 °C or 105 °C class guide
View technical data →
Thin wall multicore train cable

EN 50306-4 Thin Wall Multicore Rolling Stock Cable

EN 50306-4 Thin Wall Multicore Rolling Stock Cable is a rolling stock cable construction for control harnesses, driver desks, switchboards, using class 5 tinned copper conductor, thin wall halogen-free core insulation and thin wall halogen-free rolling stock sheath.

  • EN 50306 thin wall multicore
  • EN 50306-4
  • 300/500 V
  • 90 °C or 105 °C class guide
View technical data →
Thin wall screened multipair cable

EN 50306-4 Thin Wall Multipair Screened Rolling Stock Cable

EN 50306-4 Thin Wall Multipair Screened Rolling Stock Cable is a rolling stock cable construction for signal pairs, control circuits, driver desks, using class 5 tinned copper conductor, thin wall halogen-free pair insulation, individual pair screen and overall railway sheath and thin wall halogen-free rolling stock sheath.

  • EN 50306 thin wall multipair screened
  • EN 50306-4
  • 300/500 V
  • 90 °C or 105 °C class guide
View technical data →
Railway Ethernet and data cable

EN 45545 Railway Ethernet Data Cable

EN 45545 Railway Ethernet Data Cable is a rolling stock cable construction for passenger information, cctv, ethernet backbone, using solid or stranded tinned copper data conductor, foam or solid data pair insulation, foil and braid pair shielding and halogen-free rail data outer sheath.

  • EN 45545 rail Ethernet cable
  • EN 45545-2 / IEC 61156 reference
  • Data circuit
  • -40 °C to +90 °C guide
View technical data →
Train bus and serial data cable

Train Bus MVB WTB Rolling Stock Cable

Train Bus MVB WTB Rolling Stock Cable is a rolling stock cable construction for mvb train bus, wtb train bus, can systems, using stranded tinned copper data conductor, foam or solid bus pair insulation, foil and braid bus shielding and halogen-free rolling stock bus cable sheath.

  • Train bus cable
  • IEC 61375 / EN 45545-2 reference
  • Data circuit
  • -40 °C to +90 °C guide
View technical data →
Moving-route rail vehicle cable

Continuous Flex Rail Vehicle Control Cable

Continuous Flex Rail Vehicle Control Cable is a rolling stock cable construction for door systems, bogies, gangways, using extra fine tinned copper conductor, flexible halogen-free core insulation and abrasion, oil and weather resistant rail flex sheath.

  • Rail flex control cable
  • EN 45545-2 rail flexible cable reference
  • 300/500 V
  • -40 °C to +90 °C moving guide
View technical data →

Related Product Family