Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
EN 50264-3-1 Single Core Rolling Stock Cable 600 V cable construction reference

Standard wall single-core rail vehicle cable

EN 50264-3-1 Single Core Rolling Stock Cable 600 V

EN 50264-3-1 Single Core Rolling Stock Cable 600 V is a rolling stock cable construction for control cabinets, auxiliary circuits, driver desks, using class 5 tinned copper conductor, electron-beam cross-linked halogen-free insulation and insulation-only rolling stock single core outer sheath.

Standard
EN 50264-3-1
Voltage class
0.6/1 kV
Temperature class
-45 °C to +120 °C fixed guide
Conductor
Class 5 tinned copper conductor
Insulation / jacket
Insulation-only rolling stock single core

Cable Type Data

Construction and applications.

Applications

EN 50264-3-1 Single Core Rolling Stock Cable 600 V is a rolling stock cable construction for control cabinets, auxiliary circuits, driver desks, using class 5 tinned copper conductor, electron-beam cross-linked halogen-free insulation and insulation-only rolling stock single core outer sheath.

  • Control cabinets
  • Auxiliary circuits
  • Driver desks
  • Vehicle wiring

Cable Construction

  • Class 5 tinned copper conductor
  • Electron-beam cross-linked halogen-free insulation
  • Insulation-only rolling stock single core outer sheath
  • Halogen-free low-smoke rolling stock compound system

Specifications

Select a cable size.

Each row below is a complete specification sheet — 15 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

Auxiliary and control power wiring specification references

Each row is an exact rolling stock cable cable specification sheet. Shared EN railway fire performance, conductor, insulation and sheath data are listed above.

  • Onboard dutyAuxiliary and control power wiring
  • Wall systemStandard wall single core
  • Core / pair design1 core
  • Voltage class0.6/1 kV
  • Fire classEN 45545-2 HL1 to HL3 material system
Cable referenceConductor sizeMax DC resistance at 20 °COD guide
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 1.5 mm²1.5 mm²12.7 Ω/km8.8 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 2.5 mm²2.5 mm²7.6 Ω/km9.5 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 4 mm²4 mm²4.7 Ω/km10.4 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 6 mm²6 mm²3.1 Ω/km11.2 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 10 mm²10 mm²1.83 Ω/km12.6 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 16 mm²16 mm²1.15 Ω/km14.3 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 25 mm²25 mm²0.727 Ω/km16.2 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 35 mm²35 mm²0.524 Ω/km18.0 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 50 mm²50 mm²0.387 Ω/km20.2 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 70 mm²70 mm²0.268 Ω/km22.8 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 95 mm²95 mm²0.193 Ω/km25.5 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 120 mm²120 mm²0.153 Ω/km27.8 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 150 mm²150 mm²0.123 Ω/km30.3 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 185 mm²185 mm²0.100 Ω/km33.0 mm
EN 50264 single core 600 V 0.6/1 kV Auxiliary and control power wiring 1 core 240 mm²240 mm²0.077 Ω/km36.7 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote