EN 50264 single core 600 V · 1 core 10 mm²
Ordering reference EN 50264 single core 600 V · 1 core 10 mm²
EN 50264-3-1
EN 50264 single core 600 V
Application
Control cabinets · Auxiliary circuits · Driver desks · Vehicle wiring
Construction
- 1ConductorClass 5 tinned copper conductor · 80 × Ø0.4 mm · IEC 60228 cl.5
- 2InsulationElectron-beam cross-linked halogen-free insulation
Technical parameters
Onboard dutyAuxiliary and control power wiring
Wall systemStandard wall single core
Core / pair design1 core
Conductor size10 mm²
Voltage class0.6/1 kV
Fire classEN 45545-2 HL1 to HL3 material system
Max DC resistance at 20 °C1.83 Ω/km
OD guide12.6 mm
Conductor materialClass 5 tinned copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.27 kg/m
Bend radius4 x OD fixed guide
Outer sheathInsulation-only rolling stock single core
Current rating (guide)≈ 88 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage3.5 kV a.c. 5 min
Ratings & materials
StandardEN 50264-3-1
Voltage class0.6/1 kV
Temperature class-45 °C to +120 °C fixed guide
UE Cable · China