Cable Standard

EN 50575 CPR Reaction To Fire

European Construction Products Regulation standard for the reaction-to-fire performance (Euroclasses) of cables used in construction works.

EU construction / Buildings 3 related product families 9 cable references
Applications3EU construction, Buildings, Public infrastructure
Products3LSZH Cables, Fire Resistant Cables
Cable Types9Specific cable construction pages
QuoteDetailsConstruction, marking, testing and packing notes

Scope

CPR reaction-to-fire classification (Aca to Fca) for power, control and communication cables across the EU.

Applications

  • EU construction
  • Buildings
  • Public infrastructure

Standard Selection Data

Standard focusCPR reaction-to-fire classification (Aca to Fca) for power, control and communication cables across the EU.
Typical applicationsEU construction, Buildings, Public infrastructure
Related product familiesLSZH Cables, Fire Resistant Cables, Low Voltage Power Cables
Common voltage references300/500 V to 0.6/1 kV and above; 300/500 V, 450/750 V or 0.6/1 kV; 0.6/1 kV
Construction impactCopper or aluminium conductor; XLPE, LSZH or thermoplastic insulation; Optional screen or armour; LSZH outer sheath
Datasheet requirementConfirm construction, rating, sheath, testing reference, marking and packing before quotation

Cable Construction Impact

  • Copper or aluminium conductor
  • XLPE, LSZH or thermoplastic insulation
  • Optional screen or armour
  • LSZH outer sheath
  • Copper conductor
  • Mica glass fire barrier
  • XLPE, silicone or LSZH insulation
  • Optional armour
  • XLPE or PVC insulation
  • Optional bedding

Cables Using This Standard

Use these cable pages to move from the standard reference to a quote-ready construction.

H07Z-K EN 50525 LSZH Building Wire Flexible halogen-free single core wire

H07Z-K EN 50525 LSZH Building Wire

H07Z-K EN 50525 LSZH Building Wire is a specific low smoke zero halogen cable construction for public building wiring, switchboards, control cabinets, using class 5 flexible copper conductor, cross-linked lszh compound insulation and lszh insulation only outer sheath.

  • H07Z-K LSZH building wire
  • EN 50525-3-41
  • 450/750 V
View technical data →
H07Z1-K EN 50525 LSZH Panel Wire Thermoplastic halogen-free panel wire

H07Z1-K EN 50525 LSZH Panel Wire

H07Z1-K EN 50525 LSZH Panel Wire is a specific low smoke zero halogen cable construction for switchgear, electrical cabinets, public building panels, using class 5 flexible copper conductor, thermoplastic lszh compound insulation and lszh insulation only outer sheath.

  • H07Z1-K LSZH panel wire
  • EN 50525-3-31
  • 450/750 V
View technical data →
Flexible LSZH power cable

RZ1-K LSZH Flexible Power Cable

RZ1-K LSZH Flexible Power Cable is a specific low smoke zero halogen cable construction for public buildings, industrial feeders, data centers, using class 5 flexible copper conductor, xlpe insulation and lszh polyolefin sheath.

  • RZ1-K LSZH power cable
  • IEC 60502-1
  • 0.6/1 kV
View technical data →
Fixed installation LSZH power cable

N2XH LSZH Fixed Power Cable

N2XH LSZH Fixed Power Cable is a specific low smoke zero halogen cable construction for indoor fixed wiring, public infrastructure, commercial buildings, using class 2 copper conductor, xlpe insulation and lszh outer sheath.

  • N2XH LSZH power cable
  • VDE 0276
  • 0.6/1 kV
View technical data →
Armoured LSZH power cable

BS 6724 XLPE SWA LSZH Armoured Cable

BS 6724 XLPE SWA LSZH Armoured Cable is a specific low smoke zero halogen cable construction for public buildings, transport infrastructure, industrial feeders, using class 2 copper conductor, xlpe insulation, steel wire armour and lszh outer sheath.

  • BS 6724 XLPE SWA LSZH
  • BS 6724
  • 0.6/1 kV
View technical data →
Low smoke screened control cable

LSZH Screened Control Cable

LSZH Screened Control Cable is a specific low smoke zero halogen cable construction for control panels, automation systems, public building machinery, using class 5 flexible copper conductor, lszh or halogen-free control-core insulation, tinned copper braid screen and lszh outer sheath.

  • LSZH screened control cable
  • VDE 0250
  • 300/500 V
View technical data →
Low smoke instrumentation cable

LSZH Instrumentation Cable

LSZH Instrumentation Cable is a specific low smoke zero halogen cable construction for process control, public infrastructure monitoring, data centers, using plain or tinned copper conductor, xlpe or lszh-compatible instrumentation insulation, individual and/or overall aluminium polyester screen and lszh outer sheath.

  • LSZH instrumentation cable
  • EN 50288-7
  • 300/500 V
View technical data →
Low smoke data cable

LSZH Cat6A Data Cable

LSZH Cat6A Data Cable is a specific low smoke zero halogen cable construction for data centers, office networks, public buildings, using solid or stranded copper data conductor, pe or foam pe data insulation, u/utp, f/utp or s/ftp screen according to category and lszh data cable jacket.

  • LSZH data cable
  • ISO/IEC 11801
  • Data transmission
View technical data →
Fire resistant low smoke alarm cable

Fire Resistant LSZH Alarm Cable

Fire Resistant LSZH Alarm Cable is a specific low smoke zero halogen cable construction for fire alarms, emergency lighting, life safety circuits, using plain copper conductor, mica fire barrier with lszh insulation, aluminium/polyester screen with drain wire and lszh outer sheath.

  • Fire resistant LSZH alarm cable
  • BS 7629-1
  • 300/500 V
View technical data →

Procurement Notes

When using this standard for an enquiry, confirm the full cable designation, conductor size, core count, voltage rating, sheath material, installation environment, testing requirements, cable marking and packing length. Standards help define the technical baseline, but the quote details should always match the final cable specification.

Quote Details

  • Cable type and standard reference
  • Conductor material, size and class
  • Core count, pair count or fiber count
  • Voltage rating and operating environment
  • Screening, armour, fire performance and sheath material
  • Cable marking, drum length, packing and delivery requirements

FAQ

What does EN 50575 CPR Reaction To Fire affect in cable selection?EN 50575 CPR Reaction To Fire normally affects the cable construction, application range, testing references and datasheet wording. Buyers should use the standard page together with the product page before final quotation.
Is EN 50575 CPR Reaction To Fire enough to specify a cable?Usually no. A complete enquiry should also include conductor size, core count, voltage rating, sheath material, screening or mechanical protection, installation environment and any customer-specified approvals.
Which UE Cable product families relate to EN 50575 CPR Reaction To Fire?LSZH Cables, Fire Resistant Cables, Low Voltage Power Cables