Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
Programmable Resettable Analogue Linear Heat Detection Cable cable construction reference

Programmable resettable analogue LHD cable

Programmable Resettable Analogue Linear Heat Detection Cable

Programmable Resettable Analogue Linear Heat Detection Cable is a linear heat detection cable reference for tunnels, car parks, solar pv routes, using programmable analogue resettable linear heat detector, uv resistant polymer outer jacket and standard jacket or stainless steel braid option.

Standard
EN 54-28 analogue LHD reference
Temperature class
70 °C / 158 F, 85 °C / 185 F, 100 °C / 212 F, 120 °C / 248 F, 130 °C / 266 F
Conductor
Four-core resistance-based temperature sensing cable
Insulation / jacket
UV resistant polymer outer jacket

Cable Type Data

Construction and applications.

Applications

Programmable Resettable Analogue Linear Heat Detection Cable is a linear heat detection cable reference for tunnels, car parks, solar pv routes, using programmable analogue resettable linear heat detector, uv resistant polymer outer jacket and standard jacket or stainless steel braid option.

  • Tunnels
  • Car parks
  • Solar PV routes
  • Cable galleries

Cable Construction

  • Four-core resistance-based temperature sensing cable
  • Heat-sensitive polymer detection layer
  • UV resistant polymer outer jacket
  • Standard jacket or stainless steel braid option
  • Dedicated analogue LHD controller with pre-alarm, alarm and fault outputs

Specifications

Select a cable size.

Each row below is a complete specification sheet — 5 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

Programmable resettable analogue LHD cable alarm-temperature references

Each row is an exact linear heat detection cable cable specification sheet.

  • Detector typeProgrammable analogue resettable linear heat detector
  • Sensor constructionFour-core resistance-based temperature sensing cable
  • Jacket materialUV resistant polymer outer jacket
  • ProtectionStandard jacket or stainless steel braid option
  • EnvironmentTunnels, car parks, solar PV routes, cable galleries and critical equipment monitoring
  • Controller interfaceDedicated analogue LHD controller with pre-alarm, alarm and fault outputs
  • Zone length guideUp to 500 m per controller zone
  • OD guide7.4 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote