Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
Conveyor Linear Heat Detection Cable cable construction reference

Conveyor and material-handling LHD cable

Conveyor Linear Heat Detection Cable

Conveyor Linear Heat Detection Cable is a linear heat detection cable reference for belt conveyors, transfer points, recycling lines, using digital fixed-temperature linear heat detector, nylon or fluoropolymer abrasion-resistant jacket and optional stainless steel guide wire or overbraid support.

Standard
Linear heat detection cable reference
Temperature class
78 °C / 172 F, 88 °C / 190 F, 105 °C / 221 F, 138 °C / 280 F
Conductor
Spring conductor pair with heat-sensitive polymer detection layer
Insulation / jacket
Nylon or fluoropolymer abrasion-resistant jacket

Cable Type Data

Construction and applications.

Applications

Conveyor Linear Heat Detection Cable is a linear heat detection cable reference for belt conveyors, transfer points, recycling lines, using digital fixed-temperature linear heat detector, nylon or fluoropolymer abrasion-resistant jacket and optional stainless steel guide wire or overbraid support.

  • Belt conveyors
  • Transfer points
  • Recycling lines
  • Material-handling systems

Cable Construction

  • Spring conductor pair with heat-sensitive polymer detection layer
  • Heat-sensitive polymer detection layer
  • Nylon or fluoropolymer abrasion-resistant jacket
  • Optional stainless steel guide wire or overbraid support
  • Compatible with conventional fire alarm input or addressable monitor module

Specifications

Select a cable size.

Each row below is a complete specification sheet — 4 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

Conveyor LHD cable alarm-temperature references

Each row is an exact linear heat detection cable cable specification sheet.

  • Detector typeDigital fixed-temperature linear heat detector
  • Sensor constructionSpring conductor pair with heat-sensitive polymer detection layer
  • Jacket materialNylon or fluoropolymer abrasion-resistant jacket
  • ProtectionOptional stainless steel guide wire or overbraid support
  • EnvironmentBelt conveyors, transfer points, recycling lines and material-handling fire-risk zones
  • Controller interfaceCompatible with conventional fire alarm input or addressable monitor module
  • Zone length guideUp to 300 m per monitored zone
  • OD guide6.6 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote