Fixed Temperature Nylon Linear Heat Detection Cable cable construction reference

UV and chemical resistant fixed-temperature LHD cable

Fixed Temperature Nylon Linear Heat Detection Cable

Fixed Temperature Nylon Linear Heat Detection Cable is a linear heat detection cable reference for outdoor plant, conveyors, cooling towers, using digital fixed-temperature linear heat detector, nylon protective outer jacket and abrasion, uv and chemical resistant outer jacket.

Standard
Linear heat detection cable reference
Temperature class
68 °C / 154 F, 78 °C / 172 F, 88 °C / 190 F, 105 °C / 221 F, 138 °C / 280 F
Conductor
Two low-resistance steel spring conductors separated by heat-sensitive polymer
Insulation / jacket
Nylon protective outer jacket

Cable Type Data

Construction and applications.

Applications

Fixed Temperature Nylon Linear Heat Detection Cable is a linear heat detection cable reference for outdoor plant, conveyors, cooling towers, using digital fixed-temperature linear heat detector, nylon protective outer jacket and abrasion, uv and chemical resistant outer jacket.

  • Outdoor plant
  • Conveyors
  • Cooling towers
  • Moisture-exposed fire detection

Cable Construction

  • Two low-resistance steel spring conductors separated by heat-sensitive polymer
  • Heat-sensitive polymer detection layer
  • Nylon protective outer jacket
  • Abrasion, UV and chemical resistant outer jacket
  • Compatible with conventional fire alarm input or addressable monitor module

Specifications

Select a cable size.

Each row below is a complete specification sheet — 5 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

Fixed temperature nylon LHD cable alarm-temperature references

Each row is an exact linear heat detection cable cable specification sheet.

  • Detector typeDigital fixed-temperature linear heat detector
  • Sensor constructionTwo low-resistance steel spring conductors separated by heat-sensitive polymer
  • Jacket materialNylon protective outer jacket
  • ProtectionAbrasion, UV and chemical resistant outer jacket
  • EnvironmentOutdoor plant, conveyors, cable trays, cooling towers and moisture-exposed routes
  • Controller interfaceCompatible with conventional fire alarm input or addressable monitor module
  • Zone length guideUp to 300 m per monitored zone
  • OD guide4.7 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.