Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价

Cable Standard

NF C 32-321 U-1000 R2V Cable

French standard for U-1000 R2V / RVFV 0.6/1 kV XLPE insulated, PVC sheathed power cables widely specified in France and Francophone markets.

Building power / Industrial distribution 3 related product families 9 cable references
Applications3Building power, Industrial distribution, Infrastructure
Products3Low Voltage Power Cables, Power Cables
Cable Types9Specific cable construction pages
QuoteDetailsConstruction, marking, testing and packing notes

Scope

Low voltage XLPE insulated, PVC sheathed power and armoured cables to the French U-1000 R2V / RVFV series.

Applications

  • Building power
  • Industrial distribution
  • Infrastructure

Standard Selection Data

Standard focusLow voltage XLPE insulated, PVC sheathed power and armoured cables to the French U-1000 R2V / RVFV series.
Typical applicationsBuilding power, Industrial distribution, Infrastructure
Related product familiesLow Voltage Power Cables, Power Cables, Armoured Cables
Common voltage references0.6/1 kV; 0.6/1 kV low-voltage references and 3.6/6 kV to 19/33 kV medium-voltage references; 0.6/1 kV, 6.35/11 kV and 19/33 kV armoured references
Construction impactCopper or aluminium conductor; XLPE or PVC insulation; Optional bedding; SWA or AWA armour
Datasheet requirementConfirm construction, rating, sheath, testing reference, marking and packing before quotation

Cable Construction Impact

  • Copper or aluminium conductor
  • XLPE or PVC insulation
  • Optional bedding
  • SWA or AWA armour
  • PVC or LSZH outer sheath
  • PVC, XLPE, EPR or fire-resistant insulation system by voltage class
  • Optional bedding, water blocking, screen or armour by installation route
  • PVC, LSZH, PE, MDPE, HDPE or special outer sheath
  • Low-voltage and medium-voltage constructions separated by exact specification reference
  • XLPE, PVC or fire resistant insulation system

Cables Using This Standard

Use these cable pages to move from the standard reference to a quote-ready construction.

0.6/1 kV power cable

IEC 60502-1 XLPE PVC Low Voltage Power Cable

IEC 60502-1 XLPE PVC Low Voltage Power Cable is a specific low-voltage power cable construction for power distribution, industrial plants, building feeders applications, using copper or aluminium conductor, xlpe insulation and pvc outer sheath.

  • IEC 60502-1 XLPE/PVC
  • IEC 60502-1
  • 0.6/1 kV
View technical data →
Armoured LV power cable

IEC 60502-1 XLPE SWA PVC Armoured Power Cable

IEC 60502-1 XLPE SWA PVC Armoured Power Cable is a specific low-voltage power cable construction for direct burial, industrial plants, outdoor feeders applications, using copper or aluminium conductor, xlpe insulation, steel wire armour for multicore cable and pvc outer sheath.

  • IEC 60502-1 XLPE/SWA/PVC
  • IEC 60502-1
  • 0.6/1 kV
View technical data →
British standard armoured cable

BS 5467 XLPE SWA PVC Power Cable

BS 5467 XLPE SWA PVC Power Cable is a specific low-voltage power cable construction for building services, industrial distribution, utilities applications, using plain copper or aluminium conductor, xlpe insulation, steel wire armour for multicore cable and pvc outer sheath.

  • BS 5467 XLPE/SWA/PVC
  • BS 5467
  • 0.6/1 kV
View technical data →
0.6/1 kV power cable

IEC 60502-1 XLPE PVC Low Voltage Power Cable

IEC 60502-1 XLPE PVC Low Voltage Power Cable is a specific low-voltage power cable construction for power distribution, industrial plants, building feeders applications, using copper or aluminium conductor, xlpe insulation and pvc outer sheath.

  • IEC 60502-1 XLPE/PVC
  • IEC 60502-1
  • 0.6/1 kV
View technical data →
Armoured LV power cable

IEC 60502-1 XLPE SWA PVC Armoured Power Cable

IEC 60502-1 XLPE SWA PVC Armoured Power Cable is a specific low-voltage power cable construction for direct burial, industrial plants, outdoor feeders applications, using copper or aluminium conductor, xlpe insulation, steel wire armour for multicore cable and pvc outer sheath.

  • IEC 60502-1 XLPE/SWA/PVC
  • IEC 60502-1
  • 0.6/1 kV
View technical data →
British standard armoured cable

BS 5467 XLPE SWA PVC Power Cable

BS 5467 XLPE SWA PVC Power Cable is a specific low-voltage power cable construction for building services, industrial distribution, utilities applications, using plain copper or aluminium conductor, xlpe insulation, steel wire armour for multicore cable and pvc outer sheath.

  • BS 5467 XLPE/SWA/PVC
  • BS 5467
  • 0.6/1 kV
View technical data →
Low-voltage SWA armoured cable

BS 5467 XLPE SWA PVC Multicore Armoured Cable

BS 5467 XLPE SWA PVC Multicore Armoured Cable is an armoured cable construction for mains distribution, industrial wiring, direct burial, using copper or aluminium conductor, xlpe, pvc bedding, steel wire armour for multicore cable and pvc outer sheath.

  • BS 5467 XLPE/SWA/PVC
  • BS 5467
  • 0.6/1 kV
View technical data →
BS 5467 XLPE AWA PVC Single Core Armoured Cable Low-voltage AWA single core cable

BS 5467 XLPE AWA PVC Single Core Armoured Cable

BS 5467 XLPE AWA PVC Single Core Armoured Cable is an armoured cable construction for single-core ac feeders, industrial distribution, cable ducts, using copper or aluminium conductor, xlpe, pvc bedding, aluminium wire armour for single core cable and pvc outer sheath.

  • BS 5467 XLPE/AWA/PVC
  • BS 5467
  • 0.6/1 kV
View technical data →
Low smoke SWA armoured cable

BS 6724 XLPE SWA LSZH Multicore Armoured Cable

BS 6724 XLPE SWA LSZH Multicore Armoured Cable is an armoured cable construction for public buildings, transport terminals, data centers, using copper or aluminium conductor, xlpe, lszh bedding, steel wire armour for multicore cable and lszh outer sheath.

  • BS 6724 XLPE/SWA/LSZH
  • BS 6724
  • 0.6/1 kV
View technical data →

Procurement Notes

When using this standard for an enquiry, confirm the full cable designation, conductor size, core count, voltage rating, sheath material, installation environment, testing requirements, cable marking and packing length. Standards help define the technical baseline, but the quote details should always match the final cable specification.

Quote Details

  • Cable type and standard reference
  • Conductor material, size and class
  • Core count, pair count or fiber count
  • Voltage rating and operating environment
  • Screening, armour, fire performance and sheath material
  • Cable marking, drum length, packing and delivery requirements

FAQ

What does NF C 32-321 U-1000 R2V Cable affect in cable selection?NF C 32-321 U-1000 R2V Cable normally affects the cable construction, application range, testing references and datasheet wording. Buyers should use the standard page together with the product page before final quotation.
Is NF C 32-321 U-1000 R2V Cable enough to specify a cable?Usually no. A complete enquiry should also include conductor size, core count, voltage rating, sheath material, screening or mechanical protection, installation environment and any customer-specified approvals.
Which UE Cable product families relate to NF C 32-321 U-1000 R2V Cable?Low Voltage Power Cables, Power Cables, Armoured Cables