Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to WTTC Wind Turbine Tray Cable
Cable Specification Sheet UL WTTC / TC-ER reference · Rev 01 · 2026-06

WTTC · 5 core 8 AWG / 8.37 mm²

Ordering reference  WTTC · 5 core 8 AWG / 8.37 mm²

UL WTTC / TC-ER reference WTTC

Application

Wind turbines · Nacelle wiring · Tower tray routes · Drip loops

1234
Indicative 5-core construction — copper conductor, not to scale

Construction

  1. 1
    Conductor (per core)Fine stranded bare copper conductor · 80 × Ø0.36 mm · IEC 60228 cl.5
  2. 2
    Core insulationPVC nylon or TPE insulation
  3. 3
    FillerPP filler
  4. 4
    SheathOil, sunlight and torsion resistant tray jacket

Technical parameters

Tray cable dutyWind turbine tray cable
Circuit typeWind turbine tray
Core / pair design5 core
Conductor size8 AWG / 8.37 mm²
Voltage class600 V / 1000 V
Max DC resistance at 20 °C2.21 Ω/km
OD guide16.4 mm
Conductor materialFine stranded bare copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.72 kg/m
Bend radius6 x OD fixed / torsion route by turbine design
Outer sheathOil, sunlight and torsion resistant tray jacket
Current rating (guide)≈ 70 A (Cu, multicore clipped, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.5 kV a.c. 5 min

Ratings & materials

StandardUL WTTC / TC-ER reference
Voltage class600 V / 1000 V
Temperature class90 °C to 105 °C guide
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.