WTTC · 4 core 14 AWG / 2.08 mm²
Ordering reference WTTC · 4 core 14 AWG / 2.08 mm²
UL WTTC / TC-ER reference
WTTC
Application
Wind turbines · Nacelle wiring · Tower tray routes · Drip loops
Construction
- 1Conductor (per core)Fine stranded bare copper conductor · 50 × Ø0.23 mm · IEC 60228 cl.5
- 2Core insulationPVC nylon or TPE insulation
- 3FillerPP filler
- 4SheathOil, sunlight and torsion resistant tray jacket
Technical parameters
Tray cable dutyWind turbine tray cable
Circuit typeWind turbine tray
Core / pair design4 core
Conductor size14 AWG / 2.08 mm²
Voltage class600 V / 1000 V
Max DC resistance at 20 °C8.89 Ω/km
OD guide13.6 mm
Conductor materialFine stranded bare copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.35 kg/m
Bend radius6 x OD fixed / torsion route by turbine design
Outer sheathOil, sunlight and torsion resistant tray jacket
Current rating (guide)≈ 30 A (Cu, multicore clipped, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.5 kV a.c. 5 min
Ratings & materials
StandardUL WTTC / TC-ER reference
Voltage class600 V / 1000 V
Temperature class90 °C to 105 °C guide
UE Cable · China
sales@uecable.com