Cable Specification Sheet IEC 60584-3 / ANSI MC96.1 · Rev 01 · 2026-06

PFA insulated thermocouple extension cable · 1 pair

Ordering reference  PFA insulated thermocouple extension cable · 1 pair

IEC 60584-3 / ANSI MC96.1 PFA insulated thermocouple extension cable

Application

Autoclaves · Chemical process lines · Sterilizers · High-temperature measurement

1234
Indicative 1-pair construction — copper conductor, not to scale

Construction

  1. 1
    Conductor (per core)Positive copper / negative constantan · 1 × Ø0.2 mm
  2. 2
    Pair insulationPFA insulated conductors with PFA outer jacket · Wall PFA insulated conductors with PFA outer jacket mm
  3. 3
    FillerBedding / filler
  4. 4
    SheathPFA outer jacket

Technical parameters

Thermocouple typeTX
Cable gradeExtension grade
Pair layout1 pair
Conductor construction1/0.2 mm solid / 32 AWG
Alloy combinationPositive copper / negative constantan
Insulation / sheathPFA insulated conductors with PFA outer jacket
Screen / protectionScreen-free bonded or twisted pair construction
Temperature range-75 °C to +250 °C cable route
Tolerance classIEC 60584-3 Class 1 / Class 2 option
OD guide7.7 mm
Conductor materialPositive copper / negative constantan
Cable weight147 kg/km
Bend radius6 x OD fixed guide
Outer sheathPFA outer jacket
Mutual capacitance (nom.)≈ 120 pF/m core/core · 200 pF/m core/screen (nominal)
Routine test voltage2.5 kV a.c. 5 min

Ratings & materials

StandardIEC 60584-3 / ANSI MC96.1
Voltage classInstrumentation signal circuit
Temperature class-75 °C to +250 °C cable route
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.