Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to SIHFC Screened Silicone Rubber Cable
Cable Specification Sheet VDE / IEC silicone cable reference · Rev 01 · 2026-06

SIHFC · 2 core 1.0 mm²

Ordering reference  SIHFC · 2 core 1.0 mm²

VDE / IEC silicone cable reference SIHFC

Application

Furnace controls · Sensors · Machine tools · Process control

12345
Indicative 2-core construction — copper conductor · screened, not to scale

Construction

  1. 1
    Conductor (per core)Class 5 tinned copper conductor · 32 × Ø0.2 mm · IEC 60228 cl.5
  2. 2
    Core insulationSilicone rubber core insulation
  3. 3
    FillerPP filler
  4. 4
    ShieldBraid shield (C)
  5. 5
    SheathSilicone rubber outer sheath

Technical parameters

Silicone cable dutyScreened silicone control cable
Core design2 core
Conductor size1.0 mm²
Voltage class300/500 V
Max DC resistance at 20 °C18.5 Ω/km
OD guide9.9 mm
Cable weight0.29 kg/m
Conductor materialClass 5 tinned copper conductor
Operating temperature−60 °C to +180 °C
Bend radius8 x OD flexible guide
Outer sheathSilicone rubber outer sheath
Current rating (guide)≈ 22 A (Cu, multicore clipped, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.0 kV a.c. 5 min

Ratings & materials

StandardVDE / IEC silicone cable reference
Voltage class300/500 V
Temperature class-60 °C to +180 °C screened control service
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.

Request Quote