3082A style data reference · 1 pair
Ordering reference 3082A style data reference · 1 pair
Data signal cable reference
3082A style data reference
Application
Balanced data circuits · Control systems · Low-voltage signal · Panel wiring · Building automation
Construction
- 1Conductor (per core)22 AWG 7/30 tinned copper
- 2Pair insulationFoam PE or PE
- 3FillerBedding / filler
- 4Overall screen (OS)Al/polyester foil + drain
- 5SheathPVC, LSZH or outdoor jacket option
Technical parameters
Reference style3082A style
Circuit typeProtected outdoor data route
Pair / core layout1 pair
Conductor22 AWG 7/30 tinned copper
Conductor resistance18.2 Ω/1000 ft nominal
Screen / shieldOverall foil shield + drain wire
CapacitanceLow-capacitance data reference
ImpedanceBalanced data reference
JacketOutdoor PE jacket
Voltage class300 V
Operating temperature−15 °C to +90 °C
Routine test voltage2.0 kV a.c. 5 min
Ratings & materials
StandardData signal cable reference
Voltage class300 V
UE Cable · China