Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to EN 50264-3-1 Single Core Rolling Stock Cable 1.8/3 kV
Cable Specification Sheet EN 50264-3-1 · Rev 01 · 2026-06

EN 50264 single core 1.8/3 kV · 1 core 240 mm²

Ordering reference  EN 50264 single core 1.8/3 kV · 1 core 240 mm²

EN 50264-3-1 EN 50264 single core 1.8/3 kV

Application

Converters · Main power wiring · Distribution boxes · Traction auxiliary circuits

12
Indicative single-core construction — copper conductor, not to scale

Construction

  1. 1
    ConductorClass 5 tinned copper conductor · 1221 × Ø0.5 mm · IEC 60228 cl.5
  2. 2
    InsulationElectron-beam cross-linked halogen-free insulation

Technical parameters

Onboard dutyMain power and converter wiring
Wall systemStandard wall higher-voltage single core
Core / pair design1 core
Conductor size240 mm²
Voltage class1.8/3 kV
Fire classEN 45545-2 HL1 to HL3 material system
Max DC resistance at 20 °C0.077 Ω/km
OD guide37.6 mm
Conductor materialClass 5 tinned copper conductor
Operating temperature−40 °C to +90 °C
Cable weight2.68 kg/m
Bend radius6 x OD fixed guide
Outer sheathInsulation-only rolling stock single core
Current rating (guide)≈ 643 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage12.6 kV a.c. (3.5 Uo, IEC 60502-2)

Ratings & materials

StandardEN 50264-3-1
Voltage class1.8/3 kV
Temperature class-45 °C to +120 °C fixed guide
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.

Request Quote