EN 50264 single core 1.8/3 kV · 1 core 150 mm²
Ordering reference EN 50264 single core 1.8/3 kV · 1 core 150 mm²
EN 50264-3-1
EN 50264 single core 1.8/3 kV
Application
Converters · Main power wiring · Distribution boxes · Traction auxiliary circuits
Construction
- 1ConductorClass 5 tinned copper conductor · 756 × Ø0.5 mm · IEC 60228 cl.5
- 2InsulationElectron-beam cross-linked halogen-free insulation
Technical parameters
Onboard dutyMain power and converter wiring
Wall systemStandard wall higher-voltage single core
Core / pair design1 core
Conductor size150 mm²
Voltage class1.8/3 kV
Fire classEN 45545-2 HL1 to HL3 material system
Max DC resistance at 20 °C0.123 Ω/km
OD guide31.2 mm
Conductor materialClass 5 tinned copper conductor
Operating temperature−40 °C to +90 °C
Cable weight1.74 kg/m
Bend radius6 x OD fixed guide
Outer sheathInsulation-only rolling stock single core
Current rating (guide)≈ 474 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage12.6 kV a.c. (3.5 Uo, IEC 60502-2)
Ratings & materials
StandardEN 50264-3-1
Voltage class1.8/3 kV
Temperature class-45 °C to +120 °C fixed guide
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.