Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to NR/L2/SIG/30060 Axle Counter Cable
Cable Specification Sheet NR/L2/SIG/30060 · Rev 01 · 2026-06

Axle counter cable · 1.0 mm²

Ordering reference  Axle counter cable · 1.0 mm²

NR/L2/SIG/30060 Axle counter cable

Application

Axle counters · Track vacancy detection · Trackside data links · Signal equipment

12345
Indicative 8-pair construction — copper conductor · screened, not to scale

Construction

  1. 1
    Conductor (per core)Solid or stranded copper railway signal conductor · 1 × Ø1.13 mm · IEC 60228 cl.1
  2. 2
    Pair insulationFoam or solid polyethylene signal insulation
  3. 3
    FillerBedding / filler
  4. 4
    Overall screen (OS)Al/polyester foil + drain
  5. 5
    SheathTrackside PE or LSZH outer sheath

Technical parameters

Railway dutyAxle counter evaluator link
Installation zoneTrackside trough and equipment room
Cable designXPZ multipair 8 pair rodent protected
Conductor size1.0 mm²
Voltage classSignal circuit
Max DC resistance at 20 °C18.5 Ω/km
OD guide17.1 mm
Construction designXPZ multipair 8 pair rodent protected
Conductor materialSolid or stranded copper railway signal conductor
Operating temperature−15 °C to +90 °C
Cable weight0.58 kg/m
Bend radius8 x OD fixed guide
Outer sheathTrackside PE or LSZH outer sheath
Mutual capacitance (nom.)≈ 120 pF/m core/core · 200 pF/m core/screen (nominal)
Routine test voltage2.5 kV a.c. 5 min

Ratings & materials

StandardNR/L2/SIG/30060
Voltage classSignal circuit
Temperature class-25 °C to +70 °C guide
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.

Request Quote