Axle counter cable · 0.9 mm²
Ordering reference Axle counter cable · 0.9 mm²
NR/L2/SIG/30060
Axle counter cable
Application
Axle counters · Track vacancy detection · Trackside data links · Signal equipment
Construction
- 1Conductor (per core)Solid or stranded copper railway signal conductor · 1 × Ø1.07 mm · IEC 60228 cl.1
- 2Pair insulationFoam or solid polyethylene signal insulation
- 3FillerBedding / filler
- 4Overall screen (OS)Al/polyester foil + drain
- 5SheathTrackside PE or LSZH outer sheath
Technical parameters
Railway dutyAxle counter evaluator link
Installation zoneTrackside trough and equipment room
Cable designXPZ multipair 8 pair rodent protected
Conductor size0.9 mm²
Voltage classSignal circuit
Max DC resistance at 20 °C20.6 Ω/km
OD guide16.9 mm
Construction designXPZ multipair 8 pair rodent protected
Conductor materialSolid or stranded copper railway signal conductor
Operating temperature−15 °C to +90 °C
Cable weight0.57 kg/m
Bend radius8 x OD fixed guide
Outer sheathTrackside PE or LSZH outer sheath
Mutual capacitance (nom.)≈ 120 pF/m core/core · 200 pF/m core/screen (nominal)
Routine test voltage2.5 kV a.c. 5 min
Ratings & materials
StandardNR/L2/SIG/30060
Voltage classSignal circuit
Temperature class-25 °C to +70 °C guide
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.