FGT signalling power cable · 10 mm²
Ordering reference FGT signalling power cable · 10 mm²
NR/L2/ELP/27408
FGT signalling power cable
Application
Class 2 signalling power · Trackside power · Rodent-prone routes · Rail infrastructure
Construction
- 1Conductor (per core)Class 2 stranded copper conductor · 7 × Ø1.35 mm · IEC 60228 cl.2
- 2Core insulationXLPE power insulation
- 3FillerPP filler
- 4ShieldFoil shield (B)
- 5SheathTrackside LSZH or MDPE railway outer sheath
Technical parameters
Railway dutyClass 2 signalling power
Installation zoneTrackside class 2 signalling supply
Cable designFGT enhanced 3 core
Conductor size10 mm²
Voltage class600/1000 V
Max DC resistance at 20 °C1.83 Ω/km
OD guide17.8 mm
Construction designFGT enhanced 3 core
Conductor materialClass 2 stranded copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.74 kg/m
Bend radius10 x OD fixed guide
Outer sheathTrackside LSZH or MDPE railway outer sheath
Current rating (guide)≈ 70 A (Cu, multicore clipped, 30 °C — IEC 60364-5-52 guide)
Routine test voltage3.5 kV a.c. 5 min
Ratings & materials
StandardNR/L2/ELP/27408
Voltage class600/1000 V
Temperature class90 °C conductor guide
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.