Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to NR/L2/ELP/27408 FGT Class 2 Signalling Power Cable
Cable Specification Sheet NR/L2/ELP/27408 · Rev 01 · 2026-06

FGT signalling power cable · 4 mm²

Ordering reference  FGT signalling power cable · 4 mm²

NR/L2/ELP/27408 FGT signalling power cable

Application

Class 2 signalling power · Trackside power · Rodent-prone routes · Rail infrastructure

12345
Indicative 2-core construction — copper conductor · screened, not to scale

Construction

  1. 1
    Conductor (per core)Class 2 stranded copper conductor · 7 × Ø0.85 mm · IEC 60228 cl.2
  2. 2
    Core insulationXLPE power insulation
  3. 3
    FillerPP filler
  4. 4
    ShieldFoil shield (B)
  5. 5
    SheathTrackside LSZH or MDPE railway outer sheath

Technical parameters

Railway dutyClass 2 signalling power
Installation zoneTrackside class 2 signalling supply
Cable designFGT enhanced 2 core
Conductor size4 mm²
Voltage class600/1000 V
Max DC resistance at 20 °C4.7 Ω/km
OD guide14.9 mm
Construction designFGT enhanced 2 core
Conductor materialClass 2 stranded copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.49 kg/m
Bend radius10 x OD fixed guide
Outer sheathTrackside LSZH or MDPE railway outer sheath
Current rating (guide)≈ 40 A (Cu, multicore clipped, 30 °C — IEC 60364-5-52 guide)
Routine test voltage3.5 kV a.c. 5 min

Ratings & materials

StandardNR/L2/ELP/27408
Voltage class600/1000 V
Temperature class90 °C conductor guide