Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
Stainless Steel Braided Linear Heat Detection Cable cable construction reference

Mechanically protected LHD cable

Stainless Steel Braided Linear Heat Detection Cable

Stainless Steel Braided Linear Heat Detection Cable is a linear heat detection cable reference for conveyors, escalators, tunnels, using digital fixed-temperature linear heat detector, PVC jacket under stainless steel overbraid and stainless steel overbraid mechanical protection.

Standard
Linear heat detection cable reference
Temperature class
68 °C / 154 F, 88 °C / 190 F, 105 °C / 221 F, 138 °C / 280 F, 180 °C / 356 F
Conductor
Two low-resistance spring conductors with heat-sensitive polymer detection layer
Insulation / jacket
PVC jacket under stainless steel overbraid

Cable Type Data

Construction and applications.

Applications

Stainless Steel Braided Linear Heat Detection Cable is a linear heat detection cable reference for conveyors, escalators, tunnels, using digital fixed-temperature linear heat detector, PVC jacket under stainless steel overbraid and stainless steel overbraid mechanical protection.

  • Conveyors
  • Escalators
  • Tunnels
  • Abrasive fire-risk routes

Cable Construction

  • Two low-resistance spring conductors with heat-sensitive polymer detection layer
  • Heat-sensitive polymer detection layer
  • PVC jacket under stainless steel overbraid
  • Stainless steel overbraid mechanical protection
  • Compatible with conventional fire alarm input or addressable monitor module

Specifications

Select a cable size.

Each row below is a complete specification sheet — 5 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

Stainless steel braided LHD cable alarm-temperature references

Each row is an exact linear heat detection cable cable specification sheet.

  • Detector typeDigital fixed-temperature linear heat detector
  • Sensor constructionTwo low-resistance spring conductors with heat-sensitive polymer detection layer
  • Jacket materialPVC jacket under stainless steel overbraid
  • ProtectionStainless steel overbraid mechanical protection
  • EnvironmentConveyors, escalators, tunnels, machinery guards and abrasive fire-risk routes
  • Controller interfaceCompatible with conventional fire alarm input or addressable monitor module
  • Zone length guideUp to 300 m per monitored zone
  • OD guide6.4 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote