Cable Specification Sheet AS/NZS 1802 · Rev 01 · 2026-06

Type 245 mining cable · 95 mm²

Ordering reference  Type 245 mining cable · 95 mm²

AS/NZS 1802 Type 245 mining cable

Application

Longwall shearers · Continuous miners · Longwall peripheral equipment · High-flex underground equipment

123456
Indicative medium-voltage single-core construction — copper conductor · screened, not to scale

Construction

  1. 1
    ConductorFlexible tinned copper conductor · 475 × Ø0.5 mm · IEC 60228 cl.5
  2. 2
    Conductor screenSemi-conducting layer
  3. 3
    InsulationEPR
  4. 4
    Insulation screenSemi-conducting layer
  5. 5
    Metallic screenCopper wire screen (CWS)
  6. 6
    SheathHeavy-duty reinforced mining sheath

Technical parameters

Voltage class6.6/6.6 kV
Equipment dutyPeripheral longwall cable
Core / pilot designHigh-flex pilot arrangement
Conductor size95 mm²
Max DC resistance at 20 °C0.206 Ω/km
OD guide47 mm
Construction designHigh-flex pilot arrangement
Conductor materialFlexible tinned copper conductor
Operating temperature−40 °C to +90 °C
Cable weight5.58 kg/m
Bend radius6 x OD to 8 x OD during dynamic duty
Outer sheathHeavy-duty reinforced mining sheath
Current rating (guide)≈ 353 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage12.6 kV a.c. (3.5 Uo, IEC 60502-2)

Ratings & materials

StandardAS/NZS 1802
Voltage class6.6/6.6 kV