Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
Bare Copper Class 2 Annealed Stranded Conductor cable construction reference

Annealed stranded bare copper conductor

Bare Copper Class 2 Annealed Stranded Conductor

Bare Copper Class 2 Annealed Stranded Conductor is a bare conductor reference for earthing systems, grounding grids, bonding conductors, using class 2 annealed stranded copper conductor with conductor-size-specific resistance, diameter, weight and rated-strength data.

Standard
EN 13602 / IEC 60228
Conductor
Annealed stranded bare copper conductor
Insulation / jacket
Bare copper surface

Cable Type Data

Construction and applications.

Applications

Bare Copper Class 2 Annealed Stranded Conductor is a bare conductor reference for earthing systems, grounding grids, bonding conductors, using class 2 annealed stranded copper conductor with conductor-size-specific resistance, diameter, weight and rated-strength data.

  • Earthing systems
  • Grounding grids
  • Bonding conductors
  • Lightning protection

Cable Construction

  • Class 2 annealed stranded copper conductor
  • Concentric stranded conductor construction
  • Bare copper surface
  • Supplied on wooden or steel drums

Specifications

Select a cable size.

Each row below is a complete specification sheet — 18 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

Bare copper Class 2 annealed stranded conductor conductor specifications

Each row is an exact conductor cable specification sheet.

  • Standard referenceEN 13602 Class 2
Cable referenceConductor sizeStrandingNominal diameterMax DC resistance at 20 °CRated strength guideWeight guide
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 1.5 mm²1.5 mm²Class 2 stranded copper, 7 wires1.45 mm12.1 Ω/km0.3 kN13 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 2.5 mm²2.5 mm²Class 2 stranded copper, 7 wires1.87 mm7.41 Ω/km0.5 kN22 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 4 mm²4 mm²Class 2 stranded copper, 7 wires2.36 mm4.61 Ω/km0.8 kN36 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 6 mm²6 mm²Class 2 stranded copper, 7 wires2.89 mm3.08 Ω/km1.2 kN53 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 10 mm²10 mm²Class 2 stranded copper, 7 wires3.73 mm1.83 Ω/km2 kN89 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 16 mm²16 mm²Class 2 stranded copper, 7 wires4.72 mm1.15 Ω/km3.2 kN142 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 25 mm²25 mm²Class 2 stranded copper, 7 wires5.90 mm0.727 Ω/km5 kN223 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 35 mm²35 mm²Class 2 stranded copper, 7 wires6.98 mm0.524 Ω/km7 kN312 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 50 mm²50 mm²Class 2 stranded copper, 19 wires8.34 mm0.387 Ω/km10 kN445 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 70 mm²70 mm²Class 2 stranded copper, 19 wires9.87 mm0.268 Ω/km14 kN623 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 95 mm²95 mm²Class 2 stranded copper, 19 wires11.50 mm0.193 Ω/km19 kN846 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 120 mm²120 mm²Class 2 stranded copper, 19 wires12.9 mm0.153 Ω/km24 kN1068 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 150 mm²150 mm²Class 2 stranded copper, 37 or 61 wires14.5 mm0.124 Ω/km30 kN1335 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 185 mm²185 mm²Class 2 stranded copper, 37 or 61 wires16.0 mm0.0991 Ω/km37 kN1647 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 240 mm²240 mm²Class 2 stranded copper, 37 or 61 wires18.3 mm0.0754 Ω/km48 kN2136 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 300 mm²300 mm²Class 2 stranded copper, 37 or 61 wires20.4 mm0.0601 Ω/km60 kN2670 kg/km
Bare copper Class 2 annealed stranded conductor EN 13602 Class 2 400 mm²400 mm²Class 2 stranded copper, 37 or 61 wires23.6 mm0.0470 Ω/km80 kN3560 kg/km