FAA L-824 Type C Unshielded 5 kV Airfield Cable cable construction reference

Non-shielded primary AGL cable

FAA L-824 Type C Unshielded 5 kV Airfield Cable

FAA L-824 Type C Unshielded 5 kV Airfield Cable is an airport cable construction for runway lighting, taxiway lighting, approach lighting, using class b stranded bare copper conductor, xlpe airport lighting insulation and xlpe insulation-only or colorable outer insulation system outer sheath.

Standard
FAA L-824 Type C
Voltage class
5 kV
Temperature class
90 °C wet or dry guide
Conductor
Class B stranded bare copper conductor
Insulation / jacket
XLPE insulation-only or colorable outer insulation system

Cable Type Data

Construction and applications.

Applications

FAA L-824 Type C Unshielded 5 kV Airfield Cable is an airport cable construction for runway lighting, taxiway lighting, approach lighting, using class b stranded bare copper conductor, xlpe airport lighting insulation and xlpe insulation-only or colorable outer insulation system outer sheath.

  • Runway lighting
  • Taxiway lighting
  • Approach lighting
  • Airfield series circuits

Cable Construction

  • Class B stranded bare copper conductor
  • XLPE airport lighting insulation
  • XLPE insulation-only or colorable outer insulation system outer sheath
  • Conduit, duct, aerial-supported route and direct burial where allowed

Specifications

Select a cable size.

Each row below is a complete specification sheet — 24 sizes in total. Click any row to open conductor data, resistance, dimensions, weight and ordering reference.

FAA L-824 Type C 5 kV non-shielded airfield cable references

Each row is an exact airfield lighting cable cable specification sheet. Circuit identification color, size, resistance, OD and weight are kept in the matrix.

  • Airfield dutyPrimary airfield lighting
  • Circuit typeRunway, taxiway and approach series circuit
  • FAA / reference typeFAA L-824 Type C
  • Voltage class5 kV
  • Insulation wall110 mil / 2.8 mm nominal
Cable referenceConductor sizeMax DC resistance at 20 °COD guide
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² black8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² blue8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² green8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² grey8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² orange8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² red8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² yellow8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 8 AWG / 8.37 mm² white8 AWG / 8.37 mm²2.23 Ω/km14.6 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² black6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² blue6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² green6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² grey6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² orange6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² red6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² yellow6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 6 AWG / 13.3 mm² white6 AWG / 13.3 mm²1.40 Ω/km15.7 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² black4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² blue4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² green4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² grey4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² orange4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² red4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² yellow4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
FAA L-824 Type C unshielded 5 kV Primary airfield lighting Single conductor non-shielded XLPE 4 AWG / 21.2 mm² white4 AWG / 21.2 mm²0.882 Ω/km17.2 mm
Cable Specification Sheets Exact cable references by conductor size and construction.

Specification sheets include conductor material, size, resistance, diameter, weight, construction and quotation reference.

Request Quote