Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to Duplex Overhead Service Drop ABC Cable
Cable Specification Sheet ASTM / Utility service-drop specification · Rev 01 · 2026-06

Duplex service drop ABC · Duplex service drop

Ordering reference  Duplex service drop ABC · Duplex service drop

ASTM / Utility service-drop specification Duplex service drop ABC

Application

Residential service drops · Secondary overhead service · Temporary service · Rural connections

12
Indicative 2-core construction — aluminium conductor, not to scale

Construction

  1. 1
    Conductor (per core)Class 2 stranded aluminium conductor
  2. 2
    Core insulationWeather resistant XLPE insulation · Wall Weather resistant XLPE insulation mm

Technical parameters

Voltage class600 V
Bundle layoutDuplex service drop
Phase conductor35 mm² stranded aluminium phase conductor
Neutral / messengerACSR neutral messenger 6/1
InsulationWeather resistant XLPE insulation
Screen / supportNeutral-supported service drop construction
Max DC resistance at 20 °C0.868 Ω/km
Bundle OD guide24 mm
Weight guide0.61 kg/m
Conductor materialClass 2 stranded aluminium conductor
Operating temperature−40 °C to +90 °C
Bend radius10 x OD during installation
Outer sheathBlack weather resistant XLPE surface
Routine test voltage2.5 kV a.c. 5 min

Ratings & materials

StandardASTM / Utility service-drop specification
Voltage class600 V
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.

Request Quote