Axle counter cable · 1.0 mm²
Ordering reference Axle counter cable · 1.0 mm²
NR/L2/SIG/30060
Axle counter cable
Application
Axle counters · Track vacancy detection · Trackside data links · Signal equipment
Construction
- 1ConductorSolid or stranded copper railway signal conductor · 1 × Ø1.13 mm · IEC 60228 cl.1
- 2InsulationFoam or solid polyethylene signal insulation
- 3ShieldBraid shield (C)
- 4SheathTrackside PE or LSZH outer sheath
Technical parameters
Railway dutyAxle counter link
Installation zoneTrackside trough and ballast route
Cable designXQZ star quad 1 quad rodent protected
Conductor size1.0 mm²
Voltage classSignal circuit
Max DC resistance at 20 °C18.5 Ω/km
OD guide14.0 mm
Construction designXQZ star quad 1 quad rodent protected
Conductor materialSolid or stranded copper railway signal conductor
Operating temperature−15 °C to +90 °C
Cable weight0.45 kg/m
Bend radius8 x OD fixed guide
Outer sheathTrackside PE or LSZH outer sheath
Current rating (guide)≈ 28 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.5 kV a.c. 5 min
Ratings & materials
StandardNR/L2/SIG/30060
Voltage classSignal circuit
Temperature class-25 °C to +70 °C guide
UE Cable · China
sales@uecable.com