Servo brake and temperature cable · 2 brake cores 1.0 mm²
Ordering reference Servo brake and temperature cable · 2 brake cores 1.0 mm²
UL 758
Servo brake and temperature cable
Application
Servo brake circuits · Temperature sensors · Auxiliary motor control · Machine wiring
Construction
- 1Conductor (per core)Fine-stranded flexible copper conductor · 32 × Ø0.2 mm · IEC 60228 cl.5
- 2Core insulationHigh-flex PVC or TPE auxiliary-core insulation
- 3FillerPP filler
- 4ShieldBraid shield (C)
- 5SheathPUR or PVC flexible jacket
Technical parameters
Service classBrake and auxiliary circuit
Drive functionBrake release, temperature and auxiliary control
Core / pair design2 brake cores
Power / signal size1.0 mm²
Max DC resistance at 20 °C18.5 Ω/km
ShieldingOptional overall tinned copper braid screen
OD guide11.1 mm
Conductor materialFine-stranded flexible copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.19 kg/m
Bend radius7.5 x OD dynamic / 4 x OD fixed
Outer sheathPUR or PVC flexible jacket
Current rating (guide)≈ 22 A (Cu, multicore clipped, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.0 kV a.c. 5 min
Ratings & materials
StandardUL 758
Voltage class300/500 V auxiliary
UE Cable · China