Cable Specification Sheet IEC 60794-2 / IEC 60794-3 · Rev 01 · 2026-06

FTTH PE Flat Drop Fibre · 2 fibre

Ordering reference  FTTH PE Flat Drop Fibre · 2 fibre

IEC 60794-2 / IEC 60794-3 FTTH PE Flat Drop Fibre

Application

FTTH subscriber drops · Building access · Facade routes · Last-mile connections

1234
Indicative fibre-optic loose-tube construction — not to scale

Construction

  1. 1
    Optical fibresColour-coded singlemode/multimode fibres
  2. 2
    Loose tubeGel-filled buffer tube
  3. 3
    Strength memberCentral FRP / steel rod
  4. 4
    Aramid yarnWater-blocking + aramid strength

Technical parameters

Fibre typeOS2
Fibre count2 fibre
Cable design2 fibre OS2 FTTH flat drop cable
InstallationSubscriber drop, facade, indoor/outdoor access and last-mile routes
Strength memberFRP or steel strength members
ProtectionFlat drop tensile members
Sheath / jacketLSZH or PE drop jacket
Optical attenuation0.36 dB/km at 1310 nm, 0.22 dB/km at 1550 nm max
Tensile load600 N to 1000 N installation load guide
Crush resistance1000 N/100 mm guide
OD guide2.5 x 3.9 mm
Construction design2 fibre OS2 FTTH flat drop cable
Conductor materialOptical fibre element
Operating temperature−15 °C to +90 °C
Cable weight33 kg/km
Bend radius10 x OD during installation / 5 x OD installed
Routine test voltage2.5 kV a.c. 5 min