Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to Offshore Communication And Fibre Oil And Gas Cable
Cable Specification Sheet IEC 60794 / IEC 61158 · Rev 01 · 2026-06

Offshore Communication Fibre · 2 pair data AWG22 data pair

Ordering reference  Offshore Communication Fibre · 2 pair data AWG22 data pair

IEC 60794 / IEC 61158 Offshore Communication Fibre

Application

Offshore automation networks · Fieldbus systems · Control room links · Optical communication

12345
Indicative fibre-optic loose-tube construction — not to scale

Construction

  1. 1
    Conductor (per core)
  2. 2
    Pair insulation
  3. 3
    FillerBedding / filler
  4. 4
    Overall screen (OS)Al/polyester foil + drain
  5. 5
    SheathSHF1 or LSZH communication sheath

Technical parameters

Service packageOffshore communication, fieldbus and optical package
StandardIEC 60794 / IEC 61158
Cable designScreened data, fieldbus and optical communication cable
Voltage / signal classSignal / data
Pair / core design2 pair data
Conductor / fibreAWG22 data pair
Screen / protectionFoil/braid screen or dielectric optical protection
Fire and safety ratingLSZH, low smoke and flame retardant
Oil, mud and environmentOffshore automation, control network and telecom routes
SheathSHF1 or LSZH communication sheath
Electrical / optical referenceData-pair impedance, capacitance and continuity reference
OD guide24.2 mm
Conductor materialPlain or tinned copper conductor
Operating temperature−15 °C to +90 °C (fire-rated)
Cable weight1233 kg/km
Bend radius8 x OD during installation
Outer sheathSHF1 or LSZH communication sheath
Max DC resistance at 20 °C36.00 Ω/km
Mutual capacitance (nom.)≈ 52 pF/m (nominal)
Routine test voltage2.5 kV a.c. 5 min

Ratings & materials

StandardIEC 60794 / IEC 61158
Voltage classSignal / data
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.