Cable Specification Sheet IEC 60092-376 · Rev 01 · 2026-06

IEC 60092-376 instrumentation cable · 1.0 mm²

Ordering reference  IEC 60092-376 instrumentation cable · 1.0 mm²

IEC 60092-376 IEC 60092-376 instrumentation cable

Application

Marine instrumentation · Control systems · Alarm circuits · Process signal circuits

123456
Indicative 2-pair construction — copper conductor · screened, not to scale

Construction

  1. 1
    Conductor (per core)1.0 mm² · 7 × Ø0.43 mm · IEC 60228 cl.2
  2. 2
    Pair insulationXLPE, EPR or HEPR
  3. 3
    Individual screen (IS)Al/polyester foil + tinned-copper drain
  4. 4
    FillerBedding / filler
  5. 5
    Overall screen (OS)Al/polyester foil + drain
  6. 6
    SheathSHF1 or SHF2

Technical parameters

Circuit typeInstrumentation
Core / pair design2 pair
Conductor size1.0 mm²
Voltage class150/250 V, 250 V or 300/500 V
Fire / mud behaviorFlame retardant, low smoke and halogen-free sheath options
OD guide17 mm
Operating temperature−40 °C to +90 °C
Cable weight0.36 kg/m
Bend radius8 x OD to 12 x OD during installation
Outer sheathSHF1 or SHF2
Max DC resistance at 20 °C18.10 Ω/km
Mutual capacitance (nom.)≈ 120 pF/m core/core · 200 pF/m core/screen (nominal)
Routine test voltage2.0 kV a.c. 5 min

Ratings & materials

StandardIEC 60092-376
Voltage class150/250 V, 250 V or 300/500 V
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.