Intemp 250 · 1 core 35 mm²
Ordering reference Intemp 250 · 1 core 35 mm²
BS 3G 210 reference
Intemp 250
Application
Furnaces · Industrial heaters · Power plants · Hot process equipment
Construction
- 1ConductorNickel-plated copper conductor · 7 × Ø2.52 mm · IEC 60228 cl.2
- 2InsulationMica glass tape insulation
- 3ShieldBraid shield (C)
- 4SheathGlass fibre braid covering
Technical parameters
Heat dutyRadiant heat and furnace-adjacent wiring
Core design1 core
Conductor size35 mm²
Voltage class300/500 V
Max DC resistance at 20 °C0.524 Ω/km
OD guide13.6 mm
Cable weight0.65 kg/m
Conductor materialNickel-plated copper conductor
Operating temperature−60 °C to +180 °C
Bend radius6 x OD fixed guide
Outer sheathGlass fibre braid covering
Current rating (guide)≈ 185 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.0 kV a.c. 5 min
Ratings & materials
StandardBS 3G 210 reference
Voltage class300/500 V
Temperature classUp to +250 °C heat-resistant service
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.