Cable Specification Sheet BS 3G 210 reference · Rev 01 · 2026-06

Intemp 250 · 1 core 0.75 mm²

Ordering reference  Intemp 250 · 1 core 0.75 mm²

BS 3G 210 reference Intemp 250

Application

Furnaces · Industrial heaters · Power plants · Hot process equipment

1234
Indicative single-core construction — copper conductor · screened, not to scale

Construction

  1. 1
    ConductorNickel-plated copper conductor · 7 × Ø0.37 mm · IEC 60228 cl.2
  2. 2
    InsulationMica glass tape insulation
  3. 3
    ShieldBraid shield (C)
  4. 4
    SheathGlass fibre braid covering

Technical parameters

Heat dutyRadiant heat and furnace-adjacent wiring
Core design1 core
Conductor size0.75 mm²
Voltage class300/500 V
Max DC resistance at 20 °C24.7 Ω/km
OD guide6.8 mm
Cable weight0.28 kg/m
Conductor materialNickel-plated copper conductor
Operating temperature−60 °C to +180 °C
Bend radius6 x OD fixed guide
Outer sheathGlass fibre braid covering
Routine test voltage2.0 kV a.c. 5 min

Ratings & materials

StandardBS 3G 210 reference
Voltage class300/500 V
Temperature classUp to +250 °C heat-resistant service