Defence communication screened pair cable · 0.5 mm²
Ordering reference Defence communication screened pair cable · 0.5 mm²
Defence communication cable reference
Defence communication screened pair cable
Application
Command systems · Shelters · Vehicles · Field equipment
Construction
- 1Conductor (per core)Tinned copper signal conductor · 16 × Ø0.2 mm · IEC 60228 cl.5
- 2Pair insulationPE, XLPE or LSZH signal insulation
- 3Individual screen (IS)Al/polyester foil + tinned-copper drain
- 4FillerBedding / filler
- 5Overall screen (OS)Al/polyester foil + drain
- 6SheathLSZH, PUR or PE defence outer sheath
Technical parameters
Mission dutyCommand, control and signal communication
PlatformShelter, vehicle and fixed defence equipment
Cable design8 pair screened twisted pair
Conductor / fibre0.5 mm²
Electrical reference100 Ω to 120 Ω signal reference by protocol
Shield / protectionFoil screen with drain wire and optional braid
Environment classEMI controlled indoor/outdoor equipment route
OD guide15.4 mm
Construction design8 pair screened twisted pair
Conductor materialTinned copper signal conductor
Operating temperature−40 °C to +90 °C
Cable weight0.44 kg/m
Bend radius8 x OD fixed guide
Outer sheathLSZH, PUR or PE defence outer sheath
Max DC resistance at 20 °C36.00 Ω/km
Mutual capacitance (nom.)≈ 120 pF/m core/core · 200 pF/m core/screen (nominal)
Routine test voltage2.5 kV a.c. 5 min
Ratings & materials
StandardDefence communication cable reference
Voltage classSignal and data circuit
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.