Def Stan 61-12 equipment wire · 1.5 mm²
Ordering reference Def Stan 61-12 equipment wire · 1.5 mm²
Def Stan 61-12 reference
Def Stan 61-12 equipment wire
Application
Military vehicles · Aircraft equipment · Electronics bays · Data processors
Construction
- 1Conductor (per core)Tinned copper conductor · 7 × Ø0.52 mm · IEC 60228 cl.2
- 2Core insulationDefence-grade thin wall or standard wall insulation
- 3FillerPP filler
- 4SheathLSZH, HFFR or equipment-wire jacket system
Technical parameters
Mission dutyHigh-density equipment wiring
PlatformVehicle, aircraft equipment and electronics bay
Cable design7 core
Conductor / fibre1.5 mm²
Electrical reference13.3 Ω/km conductor resistance
Shield / protectionCompact LSZH or HFFR construction
Environment classCompact equipment, vibration and low-smoke duty
OD guide12.2 mm
Construction design7 core
Conductor materialTinned copper conductor
Operating temperature−15 °C to +90 °C
Cable weight0.36 kg/m
Bend radius4 x OD to 6 x OD fixed guide
Outer sheathLSZH, HFFR or equipment-wire jacket system
Max DC resistance at 20 °C12.10 Ω/km
Current rating (guide)≈ 22 A (Cu, multicore clipped, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.5 kV a.c. 5 min
Ratings & materials
StandardDef Stan 61-12 reference
Voltage classEquipment wire voltage by part reference
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.