FLR4G · 2.5 mm²
Ordering reference FLR4G · 2.5 mm²
ISO 6722
FLR4G
Application
Engine harnesses · Vehicle body wiring · Heat exposed low-voltage circuits · OEM harnesses
Construction
- 1ConductorBare or tinned copper conductor · 50 × Ø0.25 mm
- 2InsulationEVA · Wall 0.35 mm
Technical parameters
Cross-section2.5 mm²
No. and dia. of wires50/0.25
Conductor dia. max. (mm)2.05
Max DC resistance at 20 °C (Ω/km)7.6 Ω/km
Insulation min. wall (mm)0.35
Overall diameter approx. (mm)2.75
Approx. cable weight (kg/km)25.4
Operating temperature−40 °C to +90 °C
Current rating (guide)≈ 38 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage2.0 kV a.c. 5 min
Ratings & materials
StandardISO 6722
Voltage class60 V automotive low-voltage circuits
Temperature class-40 °C to +125 °C typical class
Colour / markingBlack, red, blue, yellow, green, white, brown or specified color
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.