2 kV primary AGL cable · 4 mm²
Ordering reference 2 kV primary AGL cable · 4 mm²
Airfield primary lighting application reference
2 kV primary AGL cable
Application
Primary lighting · Runway circuits · Taxiway circuits · Airfield pavement routes
Construction
- 1ConductorClass 2 or Class 5 copper conductor · 7 × Ø0.85 mm · IEC 60228 cl.2
- 2InsulationXLPE primary airfield insulation · Wall 2 kV primary lighting wall guide mm
Technical parameters
Airfield dutyPrimary airfield lighting
Circuit type2 kV primary lighting circuit
FAA / reference type2 kV AGL application reference
Conductor size4 mm²
Voltage class2 kV
Insulation wall2 kV primary lighting wall guide
Max DC resistance at 20 °C4.61 Ω/km
OD guide14.3 mm
Construction designSingle conductor XLPE PVC outer sheath
Conductor materialClass 2 or Class 5 copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.24 kg/m
Bend radius10 x OD fixed guide
Outer sheathPVC outer sheath
Current rating (guide)≈ 50 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage12.6 kV a.c. (3.5 Uo, IEC 60502-2)
Ratings & materials
StandardAirfield primary lighting application reference
Voltage class2 kV
Temperature class90 °C conductor guide
UE Cable · China
sales@uecable.com
Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.