Products产品中心 Standards标准库 Industries应用行业 Insights资讯 Generator线缆生成器 About关于我们
Request a Quote索取报价
← Back to 2 kV Primary Airfield Lighting Cable
Cable Specification Sheet Airfield primary lighting application reference · Rev 01 · 2026-06

2 kV primary AGL cable · 10 mm²

Ordering reference  2 kV primary AGL cable · 10 mm²

Airfield primary lighting application reference 2 kV primary AGL cable

Application

Primary lighting · Runway circuits · Taxiway circuits · Airfield pavement routes

12
Indicative single-core construction — copper conductor, not to scale

Construction

  1. 1
    ConductorClass 2 or Class 5 copper conductor · 7 × Ø1.35 mm · IEC 60228 cl.2
  2. 2
    InsulationXLPE primary airfield insulation · Wall 2 kV primary lighting wall guide mm

Technical parameters

Airfield dutyPrimary airfield lighting
Circuit type2 kV primary lighting circuit
FAA / reference type2 kV AGL application reference
Conductor size10 mm²
Voltage class2 kV
Insulation wall2 kV primary lighting wall guide
Max DC resistance at 20 °C1.83 Ω/km
OD guide16.1 mm
Construction designSingle conductor XLPE HDPE outer sheath
Conductor materialClass 2 or Class 5 copper conductor
Operating temperature−40 °C to +90 °C
Cable weight0.31 kg/m
Bend radius10 x OD fixed guide
Outer sheathHDPE outer sheath
Current rating (guide)≈ 88 A (Cu, 1-core free air, 30 °C — IEC 60364-5-52 guide)
Routine test voltage12.6 kV a.c. (3.5 Uo, IEC 60502-2)

Ratings & materials

StandardAirfield primary lighting application reference
Voltage class2 kV
Temperature class90 °C conductor guide
UE Cable · China sales@uecable.com

Confirm quantity, colour, printing, packing length, delivery country and required test documents when sending an enquiry.

Request Quote